Window Meanings

N.
Read/
Data
Write
Type
000
R/W
L
Start/Stop
(in remote/
mode the win-
dow is a read
only)
001
R/W
L
Low Speed
Activation (in
remote/ mode
the window is
a read only)
008
R/W
L
Remote
or Serial con-
figuration
100
R/W
L
Soft Start
(write only
in Stop
condition)
101
R/W
N
R1 Set Point
type
102
R/W
N
R1 Set Point
valve
(expressed in
Hz, W or s)
103
R/W
N
Set Point de-
lay: time be-
tween the
pump start and
the set point
check (sec-
onds)
104
R/W
L
Set Point sig-
nal activation
type: the signal
can be "high
level active" or
"low level ac-
tive"
105
R/W
N
Set point
hysteresis
(in % of value)
106
R/W
L
Water cooling
(write only in
stop)
107
R/W
L
Active Stop
(write only in
stop)
108
R/W
N
Baud rate
109
W
L
cycle time/
cycle number
reset
110
R/W
L
(default = 1)
Description
Admitted
Values
Start = 1
Stop = 0
No = 0
Yes = 1
(default = 0)
Remote = 1
Serial = 0
(default = 1)
YES = 1
NO = 0
0 = Frequency
1 = Power
2 = Time
3 = Normal
4 =Pressure
(default = 0)
(default = 867)
0 to 999999
(default = 0)
0 = high level ac-
tive
1 = low level ac-
tive
(default = 0)
0 to 100
(default = 2)
0 = NO
1 = YES
0 = NO
1 = YES
(default = 0)
600 = 0
1200 = 1
2400 = 2
4800 = 3
9600 = 4
(default = 4)
Pump life/
To reset write '1'
Interlock type
Impulse = 0
Continuous = 1
N.
Read/
Write
Type
111
R/W
117
R/W
120
R/W
122
R/W
125
R/W
126
R/W
147
R/W
155
R
157
R/W
161
R/W
162
R/W
163
R/W
70/74
TECHNICAL INFORMATION
Data
Description
L
Analog out-
0 = frequency
put type:
1 = power
output volt-
(default = 1)
age signal
proportional
2 = Pump
to frequency
or power
3 = Pressure
N
Low Speed
1100 to "Maxi-
frequency
mum rotational
(Hz)
frequency"
(win 120)
(default = 1100)
N
Rotational
1100 to 1350
frequency
(default = 1350)
setting (Hz)
L
Set vent
0 = Closed
valve on/off
1 = Open
(default = 1)
L
Set the vent
Automatic = 0
valve
(see note 1.)
operation
On command = 1
(see note 2.)
N
Vent valve
0 to 65535
opening delay
(corresponding to
(expressed in
0 to 13107 sec)
0.2 sec)
(default = 15)
N
Vent open
0 = infinite
time
1 bit = 0.2 sec
See "vent
1 to 65535
connector"
paragraph
N
Power limit
watt
applied
Read the
maximum
allowable
power
N
Gas load
Ø = N
type
1 = Ar
Select the
gas load to
the pump
Pressure
N
0 to 10
Reading Con-
0 = 0
nection Factor
10 = 1 = N
Table A1 Ap-
pendix A Eye-
Sys Manual
A
R1 Set Point
Pressure
Valve
Valid if Win.
101 = 4
Format X.X
E. XX
Where X = 0
to 9
s = + or -
N
Pressure unit
0 = mBar
of measure
1 = Pa
2 = Torr
87-901-010-01
Admitted
Values
temperature
2
2