iNSTallaTiON
Settings
f Insert the right side panel at the bottom and pivot the top
f
towards the appliance.
f Hook the top of the side panel into the cover and push it
f
backwards.
Make sure that the side panel rests on the mounting plate of
the programming unit.
f Secure the side panel using the 3 screws with serrated
f
washers.
f Before installing the front panel, remove the protective film
f
from the programming unit.
f Insert the front panel again.
f
f Secure the front panel using the screws with serrated
f
washers.
16
| SHF
f Tighten the air discharge grille with the two quarter-turn
f
locks.
13. Settings
13.1 Configuration menu
To access the configuration menu, press and hold "Menu". After
approx. 3 seconds, actual value I1 is displayed.
Display
Description
I1-I2
Actual values
Pro1-Pro3 Time programs
P1-P5
Parameters
CodE
Contractor access
Once you have entered a four-digit code, additional actual values
and parameters reserved for qualified contractors are enabled.
access
Description
level
A0
Actual values and parameters that are enabled for the appliance
user and can therefore be accessed without a code.
A1
Actual values and parameters for the qualified contractor.
13.1.1 Enter code
The factory-set code is 1 0 0 0.
f Use "+" or "–" to call up the "CodE" menu item.
f
Access level A0 is displayed, alternating with the menu item.
f Press "OK".
f
The code entry field is displayed. The first digit flashes.
f Use "+" or "–" to enter the code 1 0 0 0. After entering each
f
digit, press "OK".
Once the code has been entered correctly, the actual values and
parameters that were previously inaccessible become visible.
13.1.2 Actual values
Display
Description
I1
Actual room temperature
I2
Relative heating time
(The counter can be reset via param-
eter P5.)
I3
Set charging level for next charge
I4
Actual charging level
access
Unit
level
A0
[°C] | [°F]
A0
[h]
A1
[%]
A1
[%]
www.stiebel-eltron.com