Settings; Temperature; Rapid Heating During Dual Circuit Operation; Cleaning, Care And Maintenance - Stiebel Eltron FCR 21/60 Utilisation Et Installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24
OPERATION

Settings

4.
Settings
4.1

Temperature

The temperature can be variably adjusted. In the delivered con-
dition, temperature selection is limited. This limitation can be
cancelled by a qualified contractor (see chapter "Installation /
Settings").
You can interrupt the heating process by setting the temperature
selector to "cold".
• Cold
I Low temperature setting, 35 °C
E Recommended setting for energy saving,
low scaling, 60 °C
III maximum temperature setting, 82 °C
Depending upon the system, the temperatures may vary from
the set value.
4.2

Rapid heating during dual circuit operation

1 Pushbutton for rapid heating during dual circuit operation
If required, you can switch on the rapid heat-up function with the
pushbutton. The rapid heat-up function switches off when the se-
lected temperature has been reached and will not switch on again.
16
| FCR 21
1
5.

Cleaning, care and maintenance

f Have the electrical safety of the appliance regularly checked
by an electrician.
Scaling
f Almost every type of water will deposit lime at high tempera-
tures. Limescale will settle inside the appliance and affect its
function and service life. The heating elements must there-
fore be descaled from time to time. A qualified contractor
who is aware of the local water quality will tell you when the
next service is due.
f Check the taps/valves regularly. You can remove limescale
deposits at the tap outlets using commercially available des-
caling agents.
f Regularly activate the safety valve to prevent it from becom-
ing blocked e.g. by limescale deposits.
6.

Troubleshooting

Fault
Cause
The water does not heat
There is no power.
up.
The temperature is incor-
rectly adjusted.
The flow rate is low.
The aerator in the taps or
shower heads is dirty or
scaled-up.
Water drips from the
The valve seat is con-
safety assembly after
taminated.
heating has stopped.
If you cannot remedy the fault, notify your heating contractor. To
facilitate and speed up your enquiry, please provide the serial
number from the type plate (no. 000000-0000-000000):
Remedy
Check the fuses/MCBs in
your fuse box.
Check the temperature
setting.
Clean or descale the
aerator or shower head.
Depressurise and isolate
the appliance from the
power supply. Request
your qualified contractor
to attend.
FCR
Nr.: 000000 - 0000 - 000000
Made in Germany
FCR
Nr.: 000000 - 0000 - 000000
Made in Germany
www.stiebel-eltron.com

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Fcr 21/120

Table des Matières