OpEraTiON

Settings

Note
If you are away for several days during the heating sea-
son, it makes sense to set a reduced room temperature,
e.g. 10 °C. This setting prevents the room temperature
from falling too low (frost protection).
4.3.1 Switching fan enabling on and off
f To switch fan enabling on or off, press the "Fan" button. If
f
fan enabling is switched on, the fan symbol appears on the
display.
5.
Settings
5.1

Standard display

The standard display is continuously displayed. If no user action
is performed for longer than 20 seconds while in the menu, the
device automatically switches to the standard display.
The default display shows the current set room temperature as
well as the "Editable parameter" symbol. You can use "+" and "–"
to change the set room temperature.
If the set room temperature corresponds to one of the values
set for the comfort or setback temperature, the symbol for the
corresponding operating mode (comfort mode, setback mode)
appears in the menu bar.
The set room temperature can also be changed manually when
in timer mode. The changed set room temperature is maintained
until the next programmed switching point is reached.
5.2

Standard menu

To access the standard menu, briefly press "Menu". You can now
call up the following menu items:
Display
Description
Adjust the charge level reducer
For days when the heat demand is lower, you can adjust the
charge volume manually in 10 % increments.
Select day of the week and time
Select comfort temperature
The comfort temperature must be set at least 0.5 °C higher
than the setback temperature.
Select setback temperature
The setback temperature must be set at least 0.5 °C lower
than the comfort temperature.
www.stiebel-eltron.com
Display
Description
Switch "Window open detection" function on and off
Select time program (Pro1, Pro2, Pro3) or deactivate (off)
Switch "Adaptive start" function on and off
Switch booster heater (accessory) on or off
To change the setting of a menu item, call the relevant menu item
up using "+" and "–". Press "OK".
As soon as the "Editable parameter" symbol appears, you can
change the setting of the menu item with "+" and "–". Press "OK"
to save the setting.
To exit the standard menu, press "Menu". The standard display
appears.
5.3

Configuration menu

Display
Description
I1-I2

Actual values

Pro1-Pro3 Time programs
P1-P5
Parameters
CodE
Contractor access
In the configuration menu, you can call up actual values, program
time programs for timer mode and set parameters.
To access the configuration menu, press and hold "Menu". After
approx. 3 seconds, actual value I1 is displayed.
Use "+" and "–" to switch between the individual actual values,
time programs and parameters.
To exit the configuration menu, press "Menu". The standard dis-
play appears.
5.3.1 Actual values
The following actual values can be called up:
Display
Description
I1
Actual room temperature
I2
Relative heating time
(The counter can be reset via parameter P5.)
Note
The counter for relative heating time  (I2) counts the
charge time in complete hours run. The counter increas-
es when the appliance has been charged for a full hour,
even if this is split between shorter periods.
Unit
[°C] | [°F]
[h]
SHF |
7