iNSTallaTiON
installation
f When raising the heating elements, ensure the through
f
holes in the side insulation are not widened by the heating
elements.
f Insert the first storage block, with the heating element cavity
f
pointing upwards, with some clearance to the r.h. thermal
insulation.
f Push the storage block up against the r.h. and back thermal
f
insulation. The long holes form the heating ducts.
f Insert the other storage blocks in the order shown.
f
f Push the cover panel taken from the interior of the appliance
f
over the upper storage blocks.

12.7 Cleaning the appliance

f Clean the appliance after installation and inserting the stor-
f
age blocks. For this, proceed as follows:
f Remove the air routing assembly.
f
www.stiebel-eltron.com
1
1 Protective temperature controller (N5)
f Lift the fan out. To do this, loosen the screws located at the
f
front on the retaining brackets.
f Observe the cable routing.
f
With some appliances, the protective temperature controller (N5)
incl. retaining bracket must be unscrewed.
Material losses
When depositing the components you have removed,
ensure that the wires are not damaged.
f Clean the floor plate and fan. Make sure not to damage the
f
fins.
f Then refit the fan, and if necessary the protective tempera-
f
ture controller and air routing assembly.
f Observe the correct cable routing.
f

12.8 Closing the appliance

f Insert the inner front panel again.
f