With digital feedback system SFD, SFD3, DSL (C-, CA, GE, GF) the temperature sensor
status is transmitted digitally and evaluated in the drive.
Provided that our configured feedback cables are used, the sensor is integrated into the mon-
itoring system of the digital servo amplifiers.

1.4.10 Vibration class

The motors are made to vibration class A according to EN 60034-14. For a speed range of
600-3600 rpm and a shaft center between 56-132 mm, this means that the actual value of the
permitted vibration severity is 1.6 mm/s.
Velocity [rpm] max. rel. Vibration Displacement [µm] max. Run-out [µm]
<= 1800
> 1800

1.4.11 Wiring technology

1.4.11.1 Connectors
Descriptions of the available connectors: (➜ # 12). Connector pinout: from (➜ # 200).
1.4.11.2 Wire cross sections
Power Cable, Combi Cable
Combi cables contain 4 power lines and 2 additional lines for motor holding brake control.
Cable
(4x1)
(4x1.5)
(4x2.5)
(4x4)
(4x6)
(4x10)
(4x16)
(4x25)
Feedback Cable
Type
Resolver, SFD
Encoder
Comcoder
Hybrid Cable
Type
SFD
SFD
SFD3/DSL (4x1.0+(2x0.34)+(2x0.75)) 4 power lines & 2 brake lines &
SFD3/DSL (4x1.5+(2x0.34)+(2x0.75))
SFD3/DSL
SFD3/DSL
Technical description of Hybrid Cable see KDN
Cross Section
Combi Cable
(4x1+(2x0.75))
(4x1.5+(2x0.75))
10.1A < I0rms  ≤ 13.1A
(4x2.5+(2x1))
13.1A < I0rms  ≤ 17.4A
(4x4+(2x1))
(4x6+(2x1))
(4x10+(2x1.5))
(4x16+(2x1.5))
(4x25+(2x1.5))
Cross Section
(4x2x0.25)
(7x2x0.25)
(8x2x0.25)
Cross Section
(4x1.0+2x(2x0.75))
(4x1.5+2x(2x0.75))
(4x2.5+(2x0.34)+(2x1.0))
(4x4+(2x0.34)+(2x1.0))
90
65
Current Carrying
Remarks
Capacity
0A < I0rms  ≤ 10.1A
The brackets (...) show the
shielding.
Current carrying capacity
17.4A < I0rms  ≤ 23A
acc. to EN60204-1:2006
23A < I0rms  ≤ 30A
Table 6, Column B2
30A < I0rms  ≤ 40A
40A < I0rms  ≤ 54A
54A < I0rms  ≤ 70A
Remarks
BiSS, EnDAT, HIPERFACE
Incremental Encoder + Hall
Remarks
4 power lines & 4 signal lines for SFD
respectively
2 signal lines for SFD3/DSL
(Hybrid
Cables).
Kollmorgen | kdn.kollmorgen.com | June 2018