IND560 PDX Installation Manual
There are two nine-pin connectors on the PROFIBUS board – use the connector and
cable routing shown in Figure 2-53.
Follow the wiring instructions included with the connector to terminate the wires.
PROFIBUS (Panel-Mount Enclosure)
The PROFIBUS connection to the panel-mount enclosure version of the option
board (Figure 2-54) can be made using either a straight or a right-angle nine-pin
connector. This connector (or an equivalent) is a standard METTLER TOLEDO part
# 64054361 for the straight connector or Siemens part # 6ES7 972-0BA41-0XA0
for the right-angle connector. These connectors are not supplied by METTLER
TOLEDO as part of the option. Attach the nine-pin mating plug to the connector.
2-32
Figure 2-53: PROFIBUS Cable Connection in Harsh Enclosure