Chapter 2.0
Installation
This Chapter covers
•
Opening the Enclosures
•
Environmental Protection
•
Mounting the Terminal
•
Installing Cables and
Connectors
•
PCB Switch Settings
•
PCB Jumper Positions
•
Capacity Label Instructions
•
Sealing the Enclosure
the three Phillips-head screws on the back panel (see Figure 2-1). The rear panel
can then be removed to gain access to the internal workings of the terminal.
Harsh Enclosure
The front panel of the harsh enclosure IND560 PDX terminal is locked in place by
four spring clips attached to the enclosure body. To gain access to the terminal's
PCB for internal wiring and setting switches, separate the front panel from the
enclosure as follows:
1. Insert the tip of a flat-blade screwdriver into one of the two slots located on the
bottom of the front panel assembly (see Figure 2-2) and gently push in toward
the enclosure. A "pop" sound is made when the cover is released.
This Chapter provides installation instructions for the IND560 PDX
terminal panel mount and harsh enclosures. Please read this appendix
thoroughly before beginning installation.
Opening the Enclosures
Procedures for opening the IND560 PDX terminal panel-mount and
harsh enclosures differ and are described in the following sections.
Panel-Mount Enclosure
The panel-mount version of the IND560 PDX is opened by removing
Figure 2-1: Opening the Panel-Mount Enclosure
2-1