Managing Rfid Cards; Adding Rfid Cards With The Master Rfid Card; Adding And Deleting Rfid Cards With The Charge App; Adding And Deleting Rfid Cards With The Service Interface - Mennekes AMTRON Xtra E Instructions D'installation

Masquer les pouces Voir aussi pour AMTRON Xtra E:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 146

7.6 Managing RFID cards

For RFID authorization, prior once-off registration of the
user's RFID card at the charging station is required.
The charging station can manage up to 100 RFID cards (2x
master, 98x users) in an internal database (whitelist).

7.6.1 Adding RFID cards with the master RFID card

You can add RFID cards to the internal database (whitelist)
with the master RFID card.
Adding a new RFID card:
1. Hold the master RFID card against the RFID symbol to
activate teach mode.
 The symbol
on the LED info bar flashes rapidly.
2. Hold the RFID card for teaching against the RFID symbol
within 30 seconds.
 The symbol
on the LED info bar flashes briefly and
then continues to flash rapidly. Teach mode is extended
by an additional 30 seconds.
3. Hold another RFID card against the RFID symbol for
teaching or hold the master RFID card against the RFID
symbol to terminate teach mode.
 The RFID card has been added to the internal database
(whitelist).
If during teach mode for an RFID card the symbol
lights up permanently, the internal database (whitelist) is
full and no more cards can be added.
7.6.2 Adding and deleting RFID cards with the
Charge APP
You can manage the database (whitelist) comfortably by
using the Charge APP on a smart phone or tablet.
7.6.3 Adding and deleting RFID cards with the
service interface
You can add RFID cards to or remove from the internal
database (whitelist) with the service interface.
 See Menu "Whitelist Operation".

7.6.4 Notes on RFID cards taught as masters

The charging station comes with two RFID cards marked as
AMTRON Master.
No charging processes can be authorised with cards
marked as masters.
The charging station requires two RFID cards taught as
masters.
If a card taught as master is deleted with the service interface
or the Charge APP, the next unknown RFID card held against
the RFID card reader will be taught as master.