Technical data

POWER SOURCE
Mains voltage ±15% (50-60Hz), V
- Autotransformer optional ±15% (50-60Hz), V
Minimum generator size, kVA
Minimum short-circuit power Ssc, MVA
1
Fuse, A
Mains current, effective, A
Mains current, max., A
Power, (100%), kVA
Power, max., kVA
Power, open circuit, W
Efficiency
Power faktor
Duty cycle
100%
20°C, A/V
Duty cycle
60%
20°C, A
Duty cycle
100%
40°C, A/V
Duty cycle
60%
40°C, A/V
Duty cycle
max.
40°C, A/%/V
Current range, A
Open circuit voltage, V
Sphere of application
2
Protection class
3
Standards C
Standards S
Dimensions C (HxWxL), mm
Dimensions S (HxWxL), mm
Weight C, kg
Weight S, kg
Wire feed speed C, m/min
WIRE FEED UNIT MWF 27
2
Wire feed speed, m/min
Torch connection
Wire-reel diameter, mm
100% duty cycle 40°C, A
 60% duty cycle 40°C, A
Wire dimension, mm
Protection class
3)
Gas pressure max., MPa (bar)
Dimensions (HxWxL), mm
Weight, kg
Standards
1)
This equipment complies with IEC 61000-3-12 provided that the short-circuit power Ssc of the grid at the interface point is greater than or equal to the stated data
in the abovementioned table. It is the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if
necessary, that the equipment is connected only to a supply with a short-circuit power Ssc greater than or equal to the stated data in the abovementioned table.
2)
S This machine meets the demand made for machines which are to operate in areas with increased hazard of electric chocks
3)
Equipment marked IP23 is designed for indoor and outdoor applications
OMEGA
2
300
3x400
-
17
10
9.0
16.9
6.3
11.5
20
0.88
0.93
MIG
MMA
230/25.5
-
245/26.3
-
175/22.8
175/27
195/23.8
195/27.8
300/24/29.0 300/20/32
15-300
0 - 300
52
S/CE
IP23
EN/IEC60974-1. EN/IEC60974-5. EN/IEC60974-10 CL.A
-
550x250x640
-
26
-
1.5-18
COOLING UNIT
1.5-27.0
Cooling efficiency C / S, W
EURO
Tank capacity, liter
300
Flow, bar - °C - l/min
420
Pressure max., bar
500
Standards
0.6-1.6
IP23
0.6 (6.0)
470x210x690
13
IEC60974-5.
IEC60974-10 CL. A
OMEGA
2
300 Boost
3x230-400. 1x230-400
-
15.5 (1x230). 16.5 (3x230). 15.5 (3x400)
0.8 (1x230). 2.1 (3x230). 2.1 (3x400)
16
11.9 (1x230). 7.0 (3x230). 3.1 (3x400)
45.3 (1x230). 26.7 (3x230). 15.0 (3x400)
2.7 (1x230). 3.8 (3x230). 3.5 (3x400)
10.4 (1x230). 11.0 (3x230). 10.3 (3x400)
30
0.84(1x230). 0.84 (3x230). 0.87 (3x400)
0.99 (1x230). 0.95 (3x230). 0.95 (3x400)
170 (1x230) 200 (3x400)
220/25 (1x230) 235/25.7 (3x400)
110/19.1 (1x230) 135/21.0 (3x400)
135/20.8 (1x230) 170/22.5 (3x400)
300/15/29.3 (1x230) 300/24/28.9 (3x400) 400/50/34.0 400/45/36.0 550/50/41.5 550/50/42.0
15-300
55
S/CE
IP23
550x250x640
-
28
-
1.5-18.0
900 / 1100
3.5
1.2 - 60 - 1.75
3
IEC60974-2.
IEC60974-10 CL.A
18
OMEGA
OMEGA
2
400
550
3x400
3x400
3x230-500
3x230-500
27
40
4.0
5.74
20
35
17.5
27.3
26.0
39.2
12.1
18.9
18.0
27.1
40
40
0.85
0.91
0.94
0.94
MIG
MMA
MIG
335
335
475/37.8
400
400
550
300/29.0
300/32.0
430/35.5
370/32.5
365/34.6
510/39.5
15-400
15-400
15-550
70
80
S/CE
S/CE
IP23
IP23
EN/IEC60974-1. EN/IEC60974-5. EN/IEC60974-10 CL.A
EN/IEC60974-1. EN/IEC60974-10 CL.A
630x250x650
630x250x650
1400x510x1020
1400x510x1020
36.5
37.5
84
85.0
0.5-27.0
0.5-27.0
EC DECLARATION OF CONFORMITY
MIGATRONIC A/S
Aggersundvej 33
9690 Fjerritslev
Denmark
hereby declare that our machine as stated below
Type: OMEGA
2
conforms to directives:
2014/35/EU
2014/30/EU
2011/65/EU
European standards:
EN/IEC60974-1
EN/IEC60974-5
EN/IEC60974-10 (Class A)
Issued in Fjerritslev 17.05.2017
Niels Jørn Jakobsen
CEO
2
MMA
475
550
430/37.2
510/40.4
15-550