6.4 Alarm configuration page

This page is used to enable monitoring of the clock, and to set which information will be sent as well
as the destination server. You can choose which parameter or parameters to define as alarms, and
configure them.
The information displayed is described below:
- Enable SNMP Trap checkbox: enables or disables automatic sending of error messages to the
SNMP Manager(s).
- SNMP Manager 1/2/3: IP addresses of servers to receive clock alarms. Using redundant SNMP
Managers increases the reliability of reception of alarms.
- Community: user-defined clock pool or domain. It is important to give all clocks on the network
the same Community name.
- Synchronisation failure: this parameter enables detection of synchronisation faults with the
"source" (Sigma Master clock).
- Hands position control: this parameter enables detection of faults in the position of the clock
hands.
- Reboot: this parameter enables detection of clock reboot.
- Temperature: this parameter enables reporting of high or low temperature threshold breaches
(variable temperature range).
- Periodic Status: this parameter enables periodic sending (configurable interval) of an alarm to
indicate to the SNMP Manager that the clock is still "alive". The alarm consists of the clock's status.