8. PROBLEMS, CAUSES AND REMEDIES

PROBLEMS
Pump does not pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6, 7, 8, 9, 10, 11, 12, 16, 17, 18
Volume rate of flow too small . . . . . . . . . . . . . . . . . . . . . . . . . . .1, 2, 3, 7, 9, 12, 13, 14
Power input too high . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1, 2, 4, 5, 8, 14
Delivery head too small . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1, 2, 3, 5, 7, 9, 12, 13, 14, 17
Pump runs erratically / loud noises . . . . . . . . . . . . . . . . . . . . . . .1, 2, 3, 10, 13, 14, 15, 17
CODE
REMEDIES
1)
1
Pump inlet or impeller blocked :
- Remove deposits in the pump and/or vessel.
2
Wrong direction of rotation :
- interchange two phases of the mains connection.
3
Internal parts worn (impeller, bearings) :
- Replace worn parts.
4
Operating voltage too low :
5
Runs on two phases (only with 3~ model) :
- Replace faulty fuse.
- Check line connections.
6
Motor not running as no voltage :
- Check electrical installation.
7
Pump inlet blocked :
- Clean pump inlet.
8
Defective motor winding or electrical line
9
Flap trap blocked :
- Clean flap trap.
10
Excessive water level drop in vessel :
- Check/replace float switch.
11
Float switch defective :
- Check float switch.
12
Shut-off fitting in compressed-air piping not or insufficiently open :
- Open shut-off fitting fully.
13
Inadmissible quantity of air or gas in the liquid being pumped
14
Defective radial bearing in motor
15
Unit-based fluctuations :
- Check piping for elastic connection.
16
Thermostat for monitoring winding has switched off because of excessive winding temperature:
- Motor switches back on automatically once cooled.
17
Pump vent blocked :
- Clean pump ventilation hole/slat.
18
Temperature of pump medium too high :
- Restore the control of the current overload in the switchgear.
To remedy faults to pressurised parts, these must be depressurised (ventilate the return-flow preventer and
1)
empty the vessel, if necessary using the manual diaphragm pump).
Check required.
2)
CODE CAUSE AND REMEDIES
:
2)
:
2)
:
2)
26