Parameter
Seasonal space heating energy efficiency class
Water heating energy efficiency class
Rated heat output
Seasonal space heating energy efficiency
Useful heat output
At rated heat output and high-temperature regime (*)
At 30% of rated heat output and low-temperature
regime (**)
Useful efficiency
At rated heat output and high-temperature regime (*)
At 30% of rated heat output and low-temperature
regime (**)
Auxiliary electricity consumption
At full load
At part load
In Stand-by mode
Other parameters
Stand-by heat loss
Pilot flame energy consumption
Annual energy consumption
Sound power level, indoors
Emissions of nitrogen oxides
For combination heaters
Declared load profile
Water heating energy efficiency
Daily electricity consumption
Daily fuel consumption
Annual electricity consumption
Annual fuel consumption
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return
temperature (at heater inlet).
Mynute Green
Symbol
25 C.S.I. E
-
A
-
A
Pnominal
25
ηs
92
P4
24,5
P1
8,0
η4
88,8
η1
96,4
elmax
40,0
elmin
13,7
PSB
2,4
Pstby
58,0
Pign
-
QHE
48
LWA
51
NOx
27
XL
ηwh
85
Qelec
0,173
Qfuel
22,934
AEC
38
AFC
17
Mynute Green
Mynute Green
30 C.S.I. E
38 C.S.I. E
A
A
A
A
29
29
93
92
29,1
29,3
9,8
9,7
88,0
88,3
98,1
97,4
59,0
52,0
19,4
17,3
2,4
2,4
58,0
58,0
-
-
54
57
54
54
24
26
XL
XL
85
84
0,105
0,157
23,097
23,124
23
34
17
17
ENGLISH
Unit
-
-
kW
%
kW
kW
%
%
W
W
W
W
W
GJ
dB
mg/kWh
%
kWh
kWh
kWh
GJ
23