Display Settings - Fronius Symo Advanced 10.0-3 208-240 Instructions De Service

Masquer les pouces Voir aussi pour Symo Advanced 10.0-3 208-240:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Daylight saving time
Activating/deactivating the automatic adjustment for daylight saving time
IMPORTANT! Only use the automatic daylight savings changeover function when there
are no LAN or WLAN-compatible system components in a Fronius Solar Net ring (e.g.
Fronius Datalogger Web, Fronius Datamanager or Fronius Hybridmanager).
Setting range
Factory setting
IMPORTANT! The time and date must be set correctly for day and year values to be dis-
played properly.

Display Settings

Setting range
Language
Setting the display language
Setting range
Night mode
Night mode controls the Fronius DATCOM and the inverter's display operation at night or
when insufficient DC voltage is available
Setting range
Factory setting
Contrast
Set the contrast on the inverter display
Setting range
Factory setting
40
on/off
on
Language / Night Mode / Contrast / Illumination
English, German, French, Spanish, Italian, Dutch, Czech, Slo-
vakian, Hungarian, Polish, Turkish, Portuguese, Romanian
AUTO / ON / OFF
OFF
AUTO:
The Fronius DATCOM operation is maintained as long as a Fronius Data-
manager is connected to an active, uninterrupted Fronius Solar Net.
The inverter display is dark during the night and can be activated by pressing
any function key.
ON:
The Fronius DATCOM operation is always maintained. The inverter pro-
vides an uninterrupted 12 V DC voltage to supply Fronius Solar Net with
power. The display is always active.
IMPORTANT! When the Fronius DATCOM night mode is ON or on AUTO
with connected Fronius Solar Net components, the power consumption of
the inverter at night increases to around 7 W.
OFF:
No Fronius DATCOM operation at night, the inverter therefore does not re-
quire any power to supply electricity to the Fronius Solar Net at night.
The inverter display is deactivated at night and the Fronius Datamanager is
not available. To activate the Fronius Datamanager, switch the inverter on
the AC side off and back on and press any function key on the inverter's dis-
play within 90 seconds.