Warning Notices
There are warning notices and safety symbols on and in the inverter. These warning notic-
Affixed to the De-
es and safety symbols must not be removed or painted over. They warn against incorrect
vice
operation, as this may result in serious injury and damage.
Text of the Warning Notices:
WARNING!
Risk of electric shock!
Non-insulated inverter
Do not remove the cover. The device does not contain any user-serviceable parts. Main-
tenance work must be carried out by a trained service technician.
Both AC and DC voltage sources terminate inside this device. Each circuit must be turned
off before carrying out maintenance work.
Wenn das Solarmodul-Feld Licht ausgesetzt wird, liefert dieses eine Gleichspannung an
dieses Gerät.
Gefahr eines elektrischen Schlages durch in Kondensatoren gespeicherte Energie. Deckel
nicht entfernen, bevor nach Abschalten aller Versorgungsquellen 5 Minuten vergangen
sind.
Ungeerdetes System: Die DC Leitungen dieses Photovoltaiksystems sind nicht geerdet
und können stromführend sein.
Information on
A dummy device should not be connected to a photovoltaic system for real operation and
Dummy Devices
may only be used for demonstration purposes.
IMPORTANT! When using a dummy device, you should never connect a live DC cable to
the DC connection sockets.
You may connect live cables or cable pieces for demonstration purposes.
Dummy devices can be recognized by their device rating plate:
12
Safety Symbols:
Risk of serious injury and damage due to
incorrect operation
Do not use the functions described here
until you have fully read and understood
the following documents:
-
These operating instructions
-
all the operating instructions for the
system components of the photovol-
taic system, especially the safety
rules
Dangerous electrical voltage
Wait for the capacitors to discharge.