Safety

DATCOM components and/or the PC/laptop may be seriously damaged if the Ether-
net or Fronius Solar Net cables are connected incorrectly to the Fronius Dataman-
ager 2.0
► The Ethernet cable should only be inserted into the LAN connection socket (colored
► The Fronius Solar Net cable should only be inserted into the Fronius Solar Net IN con-
Installing Invert-
ers with Fronius
Datamanager 2.0
in Fronius Solar
Net
*
**
***
1
2
3
4
5
22
CAUTION!
blue).
nection socket (colored red).
IN
DATCOM
IN OUT
OUT
**
5
6
2x (IN + OUT)
7
IN
Fronius Solar Net termination plug, if only one inverter with Fronius Datamanager
2.0 is linked to a PC
Fronius Solar Net cable, if an inverter with installed Fronius Datamanager 2.0 is
linked to a PC and other DATCOM components
A LAN cable is not included in the scope of supply
Connection between Fronius Datamanager 2.0 and PC via LAN or WLAN
Insert and lay the Ethernet cable in the inverter like a data communication cable in ac-
cordance with the Operating Instructions for the inverter
Insert the Ethernet cable into the LAN connection socket
Insert the Ethernet cable into the PC/laptop or into a suitable network connection sock-
et
If only one inverter with Fronius Datamanager 2.0 is linked to a PC:
Insert the Fronius Solar Net termination plug into the Fronius Solar Net IN and Solar
Net OUT connection sockets
If other Fronius DATCOM components are connected to the network, besides the in-
verter with Fronius Datamanager 2.0:
Insert the Fronius Solar Net cable into the Fronius Solar Net IN connection socket of
Fronius Datamanager 2.0
Connect the other Fronius DATCOM components
IMPORTANT! A Fronius Solar Net termination plug must be inserted into the empty
Fronius Solar Net connection sockets of the last Fronius DATCOM component.
*
***