6
TECHNICAL DATA
6.1
GENERAL TECHNICAL DATA
Model
Weight
Weight with Stone Serpentine colour
Nominal power
Efficiency
Emissions CO (13% O2)
Chimney vacuum
Exhaust gas temperature (*)
Exhaust gas flow
Combustible consumption
(*) Average temperature at nominal power. It is possible to obtain higher instantaneous exhaust gas temperatures. It is recommen-
ded to use always pipes with minimum specify T400.
6.2
EMISSIONS ACCORDING TO 15A B-VG
Model
Nominal power
Efficiency
Emissions CO (0% O2)
Emissions NOx (0% O2)
Dust Emissions (0% O2)
OGC Emissions (0% O2)
15a suitability (**)
(**) For devices with nominal power lower than 8 kW it is not requested the test with reduced power (Vereinbarung Art. 15a B-VG
– 31.12.2012)
6.3
EMISSIONS ACCORDING TO BIMSCHV
Model
Nominal power
Efficiency
Emissions CO (13% O2)
Dust emissions CO (13% O2)
BimSchV suitability
TE 60
235 kg
284 kg
8 kW
87,8 %
0,023%
11 Pa
166,1 °C
6,3 g/s
2,1 kg/h
TE 60
15a B-VG
8 kW
--
87,8 %
> 80 %
190 mg/MJ
< 1100 mg/MJ
87 mg/MJ
< 150 mg/MJ
17,8 mg/MJ
< 35 mg/MJ
3 mg/MJ
< 50 mg/MJ
Yes
--
TE 60
BImSchV
8 kW
--
87,8 %
> 73 %
285 mg/m3
< 1250 mg/m3
26,7 mg/m3
< 40 mg/m3
Yes
--
60