3.3
COMBUSTIBLE LOADING
The use of TE 60 stove is possible in two modes:
traditional or by the rear tank.
In the traditional mode, the stove makes an inter-
mittent combustion: after the fire is started, the
combustion continues till the exhaustion of the
combustible but can be kept alive with another
load and so on.
In order to extend the autonomy of the stove,
when the device is cold you can use the tank (see
picture 12). To do this, you have to open the fire
door and place 1-2 wood chunks with small size
towards the bottom of the combustion chamber,
near the tank and then use broken wood very thin
to fill the combustion chamber. Then, close the fire
door and open the cover of the tank. To allow a
correct lighting of the stove it is necessary to in-
WARNING! During the use do not open the panoramic door and the cap of the tank
otherwise you could experience a smoke emission.
1. Open the fire door and place 1-2 wood chunks
at the bottom of the combustion room.
troduce wood in the tank following this procedure:
at first, very thin broken wood chunks and then
pieces of dried small-medium size wood chunks
with maximum length 33 cm. The pieces must be
placed horizontally with care, must be placed one
over the other regularly, avoiding to place them
juxtaposed or vertically and so causing a possible
jam inside the tank or an irregular combustion.
Finally, it is mandatory to close hermetically the
cap of the tank; to light the fire, open the door
and use the products available in commerce. Dur-
ing the use do not open at all the cap of the tank.
Once the combustion is over, it is possible to use
the stove in the traditional mode, making another
load opening the fire door.
2. Fill the combustion chamber using thin broken
wood.
55