Display Menu - Cardin Elettronica 200/BL3924ESB Instructions D'utilisation

Masquer les pouces Voir aussi pour 200/BL3924ESB:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

DISPLAY MENU

Using the PROG button you can access the following functions in sequence:
- memorising the status of the dip-switches;
- display the status of the command and safety devices;
- display the number of manoeuvres;
- access the "test" mode;
- set the limited opening distance;
- set the current sensor level;
The status of the security devices TB, FTCI, FTCS
and CSP are always shown on the display.
Memorising the DIP-SWITCH settings and displaying
the firmware version ("22.")
The segments regarding the command status
(LED "ON" = command active) and safety status
(LED "ON" = safety device at rest) light up.
The number of manoeuvres appears on the display.
This number always remains visible until you
change the setting. Once 999999 has been
exceeded the lighting up of the decimal point on
the display equals 1 million + the six figure number.
PRESS
PROG
APL = Setting the limited opening space (gate1):
1 = 1/3 of the distance :
3 = 2/3 of the distance :
PRESS
PROG
SNS = Setting the current sensor.
1 = motor consumption + 2 amps
2 = motor consumption + 3 amps
3 = motor consumption + 3,5 amps
PRESS
PROG
Selecting the type of motor
inSidE =
BL3924 =
BL39rb =
PRESS
PROG
*
Parameter only present in the motors BL3924, BL39rb, inSidE and BLi824
PMT = motor power setting.
(BL3924 and BL39rb) 1-2-3-4-5-6 : (inSidE) 1-2-3-4
PRESS
PROG
Reclosing after encountering an obstacle
0 = unlimited number of closing attempts
1-3 = maximum number of closing attempts
PRESS
PROG
Setting distance from completely open position
0 = minimum distance
9 = maximum distance
PRESS
PROG
Setting the start of braking during closing
0 = braking during closing disabled
1 = minimum distance start
2 = medium distance start
3 = maximum distance start
PRESS PROG
PRESS PROG
PRESS PROG
2 = half the distance
4 = the entire distance
BL224E =
Straight arm
*
Inside operator BLi924
BL1924 =
Articulated
)
Articulated (self-locking
HL2524 =
Underground
Articulated (reversible
)
BLi824 = Inside
- selecting the type of motor;
- reclosure after encountering an obstacle;
- motor power setting
(only BL3924, BL39rb and inside);
- setting distance from completely open position;
- setting the start of braking during closing.
In the "test" mode (activated when the motor has
stopped) it is possible to check the status of the
command and safety devices.
The warning lights will activate once, each time a
"TA-TC-TAL-TD-TB-FTCI-FTCS-CSP" command is
10 sec
received. To return to the normal mode press the button
again "test" will appear, then wait for 10 seconds.
10 sec
PRESS PROG
Each time the button is pressed the
number increases (from 1 to 4).
10 sec
PRESS PROG
Each time the button is pressed the
number increases (from 1 to 3).
10 sec
PRESS PROG
Each time the button is pressed
the setting changes.
10 sec
10 sec
PRESS PROG
Each time the button is pressed the
number increases (from 0 to 3).
10 sec
PRESS PROG
Each time the button is pressed the
number increases (from 0 to 9).
10 sec
PRESS PROG
Each time the button is pressed the
number increases (from 0 to 3).
10 sec
21
10 sec
PRESS PROG
When the ("TA-TC-TD-TAL-TB- FTCI-FTCS-CSP")
inputs are activated the warning lights will light up.
10 s after the last
modification you will
automatically exit the mode
and the selected values will
be saved (eg. 4)
10 s after the last
modification you will
automatically exit the mode
and the selected values will
be saved (eg. 3)
10 s after the last
modification you will
automatically exit the mode
and the selected values will
be saved (eg. inSide )
10 s after the last
modification you will
automatically exit the mode
and the selected values will
be saved (eg. 3)
10 s after the last
modification you will
automatically exit the mode
and the selected values will
be saved (eg. 2)
10 s after the last
modification you will
automatically exit the mode
and the selected values will
be saved (eg. 4)
10 s after the last
modification you will
automatically exit the mode
and the selected values will
be saved (eg. 1)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

200/bl3924sb200/bl3924erb200/bl3924rbBl3924 série

Table des Matières