DISPLAY MODE
Using the PROG button you can access the following functions in sequence:
- memorising the status of the dip-switches;
- display the status of the command and safety devices;
- display the number of manoeuvres;
The status of the security devices
CSP are always shown on the display.
Memorising
the
DIP-SWITCH
displaying the firmware version (e.g. "V42")
The segments regarding the command status
(LED "ON" = command active) and safety status
(LED "ON" = safety device at rest) light up.
The number of manoeuvres appears on the
display. This number always remains visible until
you change the setting. Once 999999 has been
exceeded the lighting up of the decimal point on
the display equals 1 million + the six figure
number.
In the "test" mode (only activated when the motor
has stopped) it is possible to check the status of
the command and safety devices. The warning
lights
will
activate
once,
"TA-TC-TAL-TD-TB- FTCI-CSP" command is
received. In this mode you can activate serial line
communication by using the external program,
which is to be connected to the CSER connection
via cable (fig. 3). While communication is active
dashes will appear on the display; after 5 seconds
of inactivity you will be moved back to the "test"
mode. To return to the normal operating mode
press the "test" command again and wait for 10
seconds.
Limited opening setting from 1 to 9 metres (in the
example it has been set to 3 metres).
Each time "PROG" is pressed
the limited opening distance,
measured
in
metres,
increase (from 1 to 9).
10 seconds after the last
modification you will be
automatically moved out of
the mode and the selected
values will be saved (eg. 4)
TB , FTCI and
settings
and
each
time
a
10 sec
PRESS
will
10 sec
PROG
- access the "test" mode;
- set the limited opening distance;
- setting the current sensor level.
PRESS PROG
10 sec
PRESS PROG
10 sec
PRESS PROG
PRESS PROG
PRESS PROG
PRESS PROG
Each time "PROG" is pressed
the number will increase (from 1
to 9).
10 seconds after the last
modification you will be automatically
moved out of the mode and the
selected values will be saved (eg. 4)
18
When the
("TA-TC-TD-TAL-TB-FTCI-CSP")
inputs are activated the warning lights will light up.
5 sec
Connect the
programming device
PRESS PROG
(CSER) and activate it.
10 sec
Setting the current sensor.
1 = motor consumption + 1 amp
2 = motor consumption + 2 amps
3 = motor consumption + 3 amps
4 = motor consumption + 4 amps
5 = maximum torque ( max. 9 amps )
10 sec
PRESS PROG