IMPORTANT REMARKS
READ THE FOLLOWING REMARKS CAREFULLY BEFORE PROCEEDING WITH THE INSTALLA-
TION. PAY PARTICULAR ATTENTION TO ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
NOT READING THESE IMPORTANT INSTRUCTIONS COULD COMPROMISE THE CORRECT WORK-
ING ORDER OF THE SYSTEM AND CREATE DANGER SITUATIONS FOR THE USERS OF THE SYSTEM.
• These instructions are aimed at professionally qualified "installers of electrical
equipment" and must respect the local standards and regulations in force. All
materials used must be approved and must suit the environment in which the
installation is situated.
• All maintenance operations must be carried out by professionally qualified techni-
cians. Before carrying out any cleaning or maintenance operations make sure the
power is disconnected at the mains.
• This appliance must be used exclusively for the purpose for which it has been
made. "i.e. for the automation of hinged gates" with one or two gate leaves, max.
length 3,5m (5m with an articulated arm and electric lock) max. weight 400kg.
• The unit may be fitted both to the right and to the left of the passageway. This
product and all its relative components has been designed and manufactured by
Cardin Elettronica who have verified that the product conforms in every aspect to
the safety standards in force. Any non authorised modifications are to be considered
improper dangerous and the complete responsibility of the installer.
Caution! a mechanical stop buffer must be installed in the closing
position (pos. 1, fig. 5).
IMPORTANT SAFETY INSTRUCTIONS
It is the responsibility of the installer to make sure that the following public safety
conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from the main road
to eliminate possible traffic disruptions.
2) The motor must be installed on the inside of the property at a height between 1,5
and 1,8 m and not on the public side of the gate. The gates must not open onto
a public area.
3) The gate operator is designed for use on gates through which vehicles are passing.
Pedestrians should use a separate entrance.
4) The gate must be in full view when it is operating therefore controls must be situ-
ated in a position where the operator can see the gate at all times.
5) At least two warning signs (similar to the example on the right) should be placed,
where they can be easily seen by the public, in the area of the system of automatic
operation. One inside the property and one on the public side of
the installation. These signs must be indelible and not hidden by
any objects (such as tree branches, decorative fencing etc.).
6) Make sure that the end-user is aware that children and/or pets
must not be allowed to play within the area of a gate installation. If
possible include this in the warning signs.
7) Whenever a fully open gate leaf comes within at least 500 mm of a fixed structure
the space must be protected by an anticrush buffer.
8) You are advised to protect the sistem's lateral access points with pairs of (FTCS)
photocells connected to the stop input, see installation example, component 13
on page 2.
9) If you have any questions about the safety of the gate operating system, do not
install the operator. Contact your dealer for assistance.
TECHNICAL DESCRIPTION
• 200/BL3924ESB self-locking Master reduction unit with an incorporated encoder
and onboard electronics.
• 200/BL3924SB self-locking Slave reduction unit with an incorporated encoder
without onboard electronics.
• 200/BL3924ERB reversible Master reduction unit with an incorporated encoder
and onboard electronics.
• 200/BL3924RB reversible Slave reduction unit with an incorporated encoder
without onboard electronics.
- Direct current drive motor max. 24 Vdc.
- High performance, robust, permanently lubricated four-stage epicycloid reduction
unit. Internal manual release system (Cardin patent) managing the release of the
gears form the gate (emergency manoeuvre).
- A plastic framework is fixed to the reduction unit chassis and houses the elec-
tronic programmer, the battery charger, the radio frequency module, the toroidal
transformer and the special Cardin emergency batteries NiMH.
- Motor support base in zinc-plated steel.
ACCESSORIES
206/BL3924ARM Standard articulated arm (curved) in spray-painted cast aluminium.
206/BL3924DRM Straight arm with sliding guide in spray-painted cast aluminium.
206/BL3924SRM Articulated arm (curved) with joins in spray-painted cast aluminium.
980/XLSE11C Electric locking device 12 Vac/dc
IMPORTANT REMARKS
USER INSTRUCTIONS
This symbol indicates that once the products life-span has expired
it must be disposed of separately from other rubbish. The user is
therefore obliged to either take the product to a suitable differential
collection site for electronic and electrical goods or to send it back to
the manufacturer if the intention is to replace it with a new equivalent
version of the same product.
Suitable differential collection, environmental friendly treatment and disposal
contributes to avoiding negative effects on the ambient and consequently health
as well as favouring the recycling of materials. Illicitly disposing of this product by
the owner is punishable by law and will be dealt with according to the laws and
standards of the individual member nation.
During the opening/closing manoeuvre check for correct operation and activate the
emergency stop button in case of danger.
During blackouts the gate can be released and manually manoeuvred using the sup-
plied release key (see manual release pag. 6).
Periodically check the moving parts for wear and tear and grease if required using
lubricants which maintain their friction levels unaltered throughout time and are suit-
able for temperatures of -20 to +70°C.
Periodically check the correct operation of all safety devices (photoelectric cells etc.).
The appliance is not suitable for continuous operation and must be adjusted according
to the model (see technical data on page 52).
INSTALLATION INSTRUCTIONS
The minimum controls which may be installed are OPEN-STOP-CLOSE, these
controls must be installed in a location not accessible to children and outside the
opening range of the gate.
Before starting the installation of the system check that the structure which is to be
automated is in good working order and respects the local standards and regula-
WARNING
tions in force.
AUTOMATIC OPENING
KEEP CLEAR
To this end make sure that the gate is sufficiently rigid (if necessary reinforce the
structure) and that it pivots easily.
You are advised to grease all the moving parts using lubricants which maintain unal-
CHILDREN OR PETS MUST NOT
BE ALLOWED TO PLAY ON OR
tered friction characteristics over a period of time and are suitable for temperatures
NEAR THE INSTALLATION
of -20 to +70°C.
• Check the safety measures between the fixed and moving parts:
- a minimum space of 30 mm must always be left along the entire distance between
the gate and the support column measured throughout the entire opening angle
of the gate.
- make sure that the space between the bottom of the gate and the pavement
never exceeds 30 mm throughout the entire opening angle of the gate.
• The surface of the gate must not feature openings which allow a person's hand
or foot to pass through.
• Check the exact positioning of the pivots, and their good working order (the upper
and lower hinges/pivots must be aligned on the same axis).
• Work out the run of the cables according to the command and control devices
fitted and make sure the system conforms to the local standard and regulations
in force (see installation example fig.1 pag. 2).
• Check that the appliance is suitable for the size, weight and duty cycle of the gate
to which it is to be applied (see duty cycle on page 52)
ASSEMBLY PROCEDURE
The unit may be positioned either to the right or to the left of the passageway:
• Move the gate/s to the closed position.
• Choose the value "A" (fig. 4) according to the required opening angle and work
out (depending on the structural characteristics of the gate) at what height the
front bracket will be fitted to the gate.
Once the position has been established pass the connecting, power and safety
device cables through the opening "C" (fig. 6) in the column and fasten down the
motor support plate using four M8 screws and steel Ø14 rawlplugs "V1" or using
4 tie rods M10 with washers and nuts "V2". Make sure that the base "D" (fig. 6)
is perfectly square.
• Pass the cables "F" (fig. 7) through the upper cable guide "E" and fasten them
inside the base using the cable clamps "G" and the screws "H". Insert the lower
cable guide "E1".
17
IMPORTANT REMARKS
Attention! Only for EU customers - WEEE marking.