Automatic repositioning
If the programmer blocks due to an encoder count error
mer reset
, when one of the motors has been released
problem with one of the motors
flash simultaneously for 2 seconds and will then switch off for 0 seconds.
After the programmer has been in this condition for 3 minutes it will (after pre-
flashing for 0 seconds) automatically move the gate, slowly, to the completely
closed position (2 times as in the programming procedure) in order to recover the
correct position. At this point the programmer will function normally.
DISPLAY MODE
Using the PROG button you can access the following functions in
sequence:
- memorising the status of the dip-switches;
- display the status of the command and safety devices;
- display the number of manoeuvres;
The status of the security devices
FTCS
are always shown on the display.
Memorising
the
DIP-SWITCH
displaying the firmware version (e.g. "0")
The segments regarding the command status
(LED "ON" = command active) and safety status
(LED "ON" = safety device at rest) light up.
The number of manoeuvres appears on the
display. This number always remains visible until
you change the setting. Once 999999 has been
exceeded the lighting up of the decimal point on
the display equals 1 million + the six figure
number.
In the "test" mode (activated when the motor has
stopped) it is possible to check the status of the
command and safety devices. The warning lights
will
activate
once,
"TA-TC-TAL-TD-TB-FTCI-FTCS" command is
received. In this mode you can activate serial line
communication using the external program,
connected to the CSER connection via cable.
While communication is active dashes will appear
on the display; after 5 seconds of inactivity you
will be moved back to the "test" mode. To return
to the normal mode press the button again "test"
will appear, then wait for 10 seconds.
APL =
Setting the limited opening space
1 = 1/3 of the distance of gate 1
2 = half the distance of gate 1
3 = 2/3 of the distance of gate 1
4 = the entire distance of gate 1
PRESS
0 sec
PROG
10 seconds after the last
modification you will be
automatically moved out of the
mode and the selected values
will be saved (eg. 4)
Selecting the type of motor
BL1924 = Articulated operator arm
AMA24E = Articulated operator (integrated)
HL2524 = Underground operator
BL224E = Piston type operator
, after a program-
or there is a
the warning lights and indicator light will
TB
,
FTCI
and
PRESS PROG
settings
and
PRESS PROG
PRESS PROG
each
time
a
PRESS PROG
:
0 sec
Each time "PROG"
is
pressed
the
PRESS
number increases
PROG
(from 1 to 4).
PRESS
PROG
To carry out automatic repositioning without waiting for 3 minutes you may send
a (TA, TC, TAL or TD) command to the programmer. If a "TA" command is given
the positioning recovery is carried out in the opening direction.
No commands will be accepted during repositioning but the security devices will
cut in and block all movement if they go into alarm.
• To interrupt the repositioning manoeuvre and delay it for another 3 minutes,
press the "PROG" or "TB" button.
- access the "test" mode;
- set the limited opening distance;
- set the current sensor level:
- selecting the type of motor.
0 sec
0 sec
When the
inputs are activated the warning lights will light up.
5 sec
Connect the
programming device
(CSER) and activate it.
0 sec
SNS =
1 = motor consumption + 2 amp
PRESS
2 = motor consumption + 3 amps
PROG
3 = motor consumption + 3,5 amps
0 sec
Each time "PROG"
is
pressed
the
number will increase
(from 1 to 3).
0 sec
0 sec
PRESS
PROG
9
("TA-TC-TD-TAL-TB-FTCI-FTCS")
PRESS PROG
Setting the current sensor:
PRESS PROG
0 sec
10 seconds after the last modification
you will be automatically moved out
of the mode and the selected values
will be saved (eg. 3)