INDICATIONS ON THE DISPLAY (D1 - page 8)
Start up display
Shown for 2 seconds:
"CC242C" = ECU model;
Indicates the dip-switch setting
memorisation stage and firmware version
Alarm indications
System not programmed
You have to enter the programming mode to program the system
Out of position
When carrying out an installation you will have to enter programming
in order to program the gate travel distances.
During normal operation it indicates that the "repositioning" procedure will take place
when a (TA, TC, TAL or TD) is received (see page 21).
Block during encoder programming
This happens when an N.C. contact is activated (TB, FTCI, FTCS,
CSP) during encoder programming or repositioning. Once the pas-
sive state of the security devices has been reset the gate/door will
start moving again automatically. It also happens if a blackout occurs
during programming.
Safety device test error
Check the condition of the safety devices and make sure that
the alarm cuts in when an obstacle interferes with the beam (the
relative LED will switch off). In case of anomalies replace the
damaged safety device or bridge the contact and deactivate
the safety test (dip 7, 8).
Motor feed problems (M1,M2, M1+M2).
This happens when the programmer sends a com-
mand to the motor but nothing happens. Check the
connections for each motor and the condition of the
fuses "F1" and "F2". Send another opening or clos-
ing command: repositioning will be carried out (page
21); if the motor still doesn't work you may have a
mechanical or electronic problem.
Released motor (M1,M2)
This happens when you give a movement command and one
of the two motors is released. Block the released motor (see
the motor release instructions supplied with the motor) and
give a command: the repositioning procedure will be carried
out (page 21).
Encoder error (ENC1, ENC2, ENC1 + ENC2)
If it occurs during normal motor operation it means
that there is a problem with one or more encoder
signals. Check the relative connections and carry
out repositioning (page 21).
Current sensor error
When the gate is not moving this symbol means there is a
problem with the current sensor.
Operational indications
Pause time programming
Automatic programming under way
During programming this means that the system
is set to single gate leaf operation
Serial line (CSER) active (only for diagnostics)
Opening stage
Block
Pause for automatic reclosing (if activated)
Closing stage
Current sensor updating for gate leaf 1 (only during programming)
Current sensor updating for gate leaf 2 (only during programming)
Current sensor updating for gate leaf 1 + 2 (only during programming)
Opening + compensation sensor 1
Opening + compensation sensor 2
Closing + compensation sensor 1
Closing + compensation sensor 2
Test mode
Battery mode with a fully charged battery
Battery mode with an undercharged battery
Block caused by a completely discharged battery