54
AVENTICS | ED12 | R414002587–BDL–001–AB
Controlling the ED12
Danger of burns caused by hot valve coils!
Touching the valve coils during operating may lead to burns.
Let the device cool off before disassembling it.
Do not touch the device during operation.
24 V
24
A
25
D
CONTROLLER
A
26
D
27
Abb. 6: Function block diagram for ED12 with analog output and switch
output
a
Inlet connection for supply pressure
b Outlet pressure connection
c
Exhaust connection
24 Supply voltage
25 Set point input
26 Actual value output
27 Switch output
8.1

Selecting the correct supply pressure

A permanent deviation will occur if the supply pressure is less
than the outlet pressure stipulated by the electrical set point. The
electronics will reduce the power consumption and thus the max.
nominal width to prevent the ED12 from heating up.
CAUTION
Always select a supply pressure that is higher than the outlet
pressure.