Aventics ED12 Série Mode D'emploi page 51

Régulateur de pression
Masquer les pouces Voir aussi pour ED12 Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 65
12
00122959
14
13
00122960
16
15
00122961
Schaltausgang
00122911
AVENTICS | ED12 | R414002587–BDL–001–AB
For devices with an integrated XPC plug, M12:
Use a shielded cable to connect the XPC.
The shield must be connected to the plug housing.
Connect the cable at the integrated XPC (12) plug.
The ED12 can now be supplied with voltage and controlled with
a set point.
For devices with an integrated X1S plug, M12, and integrated X2M
socket, M12:
Use a shielded cable to connect the X2M.
The shield must be connected to the plug housing.
Connect the cables to the integrated X1S plug (13) and
integrated X2M socket (14).
The ED12 can now be supplied with voltage and controlled with
a set point.
Devices with two rectangular DIN EN 175301-803 plugs:
Use a shielded cable to connect the X2A (16).
The shield must be connected with the "FE" plug connection.
Connect the lines to the rectangular X1S (15) and X2A (16)
plugs.
The ED12 can now be supplied with voltage and controlled with
a set point.
As the 0 V lines are connected at the X2M and X1S or X1S and
X2A connections, the correct polarization for all plug
connections must be ensured. A short circuit will result if the
supply voltage or set point voltage has a reversed polarization.
For devices with integrated X1S plug and X2M socket:
Connect the cables at the integrated X2M socket as in the
1
2
illustration on the left.
3
The ED12 can now be supplied with voltage and the set point
4
5
set on the potentiometer.
51
Assembling the ED12

Publicité

Table des Matières
loading

Table des Matières