GB
E
Fig. 15
Fig. 18
Fig. 19
Fig. 16
ZKN1 - ZKN2
Fig. 15
Open the door and mark the centre of the door on the ceil-
ing (E).
Fig. 16
Insert the expansion plugs in the architrave (V) and raise the guide (2).
Fix the guide bracket (3) with two screws (4) by using the washers (5).
Lift the automatic system (2).
Fig. 17
Lift the guide (3) and align the bracket for the suspension to the ceiling.
The position must be in zone B, where B is 0 to 600 mm. long. Carry
out two holes Ø 10x65 mm. and insert two expansion plugs S10 (1)
and fix tight the two screws 8x60 (2) by using the two washers (2).
Fig. 17
Fig. 18
Fix (3) the door corner fitting (1) onto the rod, in a longitudi-
nal direction with respect to the position of the motor. Unlock
the motor by pulling the manual release (N).
Fig. 19 Move the motor (1) all the way forwards (3) with the rod. Align
the door corner fitting (5) with the centre of the doorway,
drilling four holes ø5mm. Adjust the limit switch (4), moving it
all the way up to the motor.