Backjump (DIP 6)
In sectional doors, you have the option to set DIP switch 6 to position ON in order to release the load from the drive system and the door. It also fa-
cilitates the activation of the emergency release.
This feature serves the purpose of supporting door and drive mechanism operation. The drive mechanism moves briefly back in a door OPEN direc-
tion once it has reached the door CLOSED final travel position, thus taking some of the strain off the other equipment.
DIP switch 6
OFF Deactivated
ON Activated
Connecting light barrier
• Permissible cable cross-section: max. 0,75 mm².
Terminal 7 + 8
Safety connection, only if DIP switch 2 is OFF
Terminal 9 + 10
Regulated DC 24 V, max. 0.1 A
Terminal 9: DC 24 V
Terminal 10: Earth
Settings: see Obstacle detection (DIP 1, 2 + 3)
Trolley board
Automatic CLOSE mode
Important to note !
Ensure compliance with standard EN 12453 (installation of light barrier) when operating in automatic CLOSE mode.
Door closes automatically after period it is kept open has elapsed. Door can only be opened but not closed by issuing command via operation of push-
button or manual remote control. When door is in process of opening, it cannot be halted by issuing a command. If a further command is issued when
door is in process of closing, it then opens fully. A command issued during period door is kept open causes period to restart from beginning.
Switching ON and OFF using DIL switch 7:
OFF Normal mode; factory-set status
ON
Period door kept open 60 seconds (cannot be altered)
Reaction of drive mechanism when safety input is triggered
In door CLOSE mode:
Drive always opens door fully, regardless of DIL switch 3 setting
In door OPEN mode:
Drive reacts in accordance with DIL switch 1 setting
Automatic CLOSE mode - option 1
Automatic CLOSE mode is activated when door reaches end OPEN position. This marks beginning of period door is kept open. Any command is-
sued during this period causes period to restart from beginning.
Settings
- DIL switch 7 ON
- other DIL switches as required
Automatic CLOSE mode + light barrier - option 2
As described above, apart from fact that drive closes door 5 seconds after light barrier has been crossed.
Settings
- DIL switch 7 + 8 ON
- other DIL switches as required
ZKN1 - ZKN2
Terminal 1 Power supply to chain
2
Power supply to rail
3 + 4
End switch gate OPEN
5
Motor cable
6
Motor cable
7 + 8
End switch gate CLOSED
31/56
GB