GB
General tips
• At delivery, all DIP switches are in OFF position.
All additional functions are disabled.
Obstacle recognition (DIP 1, 2 + 3)
If the door meets an obstacle (force cut-off) or if the safety input is interrupted (person triggering the light barrier), this is detected by the drive sy-
stem, depending on the position of the DIP switch 1.
DIP switch 1
OFF No response in the event of a safety input interruption. In the event of a force cut-off, the door is halted.
ON Drive stops door
Behaviour of drive unit during closing of door
If the door meets an obstacle (force cut-off) or if the safety input is interrupted (person triggering the light barrier), this is detected by the drive sy-
stem, depending on the position of the DIP switches 2 + 3.
DIP switch 2: Safety contact strip
OFF NC contact for light barrier
ON Button connection for button 2 (partial opening, preset opening and closing)
DIP switch 3: Behaviour of drive unit during closing of door
OFF Drive stops and opens door a little (reversal)
ON Drive stops and opens door completely
Direct socket unit
• Permissible cable cross-section: max. 1,5 mm².
Terminal 1 + 2
Transformer
Terminal 3
C-rail
Terminal 4
Chain
Use the contact only for potential-free normally closed contacts. External voltage may damage or even destroy the control unit.
Terminal 5 + 6 Push-button connection (push-button 1), potential-free NC contact
Connecting warning lamp (DIP 4)
• Permissible cable cross-section: max. 0,75 mm².
Terminal 11 + 12 Non-regulated DC 24 V (max. 34 V), max. 1 A
DIP switch 4
OFF Connected warning lamp flashes (control unit generates flashing)
ON Door status indicator
- is lit when door is not closed
- is out when door is closed
Warning time (DIP 5)
The warning lamp starts to flash after push-button is pressed or manual remote control operated during the three seconds before the drive starts up.
If the push-button is pressed again or the manual remote control is operated during the 3 seconds, the early warning period is ended prematurely.
The early warning period functions in conjunction with both internal lighting and with a connected warning lamp.
DIP switch 5
OFF Deactivated
ON Activated; internal lighting and warning lamp flash for 3 seconds.
ZKN1 - ZKN2