Fig. 8
Fig. 9
A
B
Fig. 12
D
Fig. 14
ZKN1 - ZKN2
Fig. 10
Fig. 11
C
Fig. 13
Fig. 8
Fit the bracket for the guide fixing to the ceiling as shown in the figure.
Fig. 9
Insert the fixing bracket (1) in the guide (2).
Fig. 10
Fix the bracket, guide angle (2) with the screw (1) and the nut (3) to terminal
(4).
Fig. 11
Determine the highest opening point of the door (THP): the ceiling must be
above this point, and at a distance of at least 35 mm.
The distance between the maximum door opening point and the lower guide
must be included between 5 mm (min.) and 65 mm. (max), while the thrust
arm must have an angle of 30°.
Fig. 12
The guide can be fixed either on the architrave (A) either to the ceiling (B).
Fig. 13
Measure the centre of the door (C) and mark the point on the door, on the lin-
tel and on the ceiling.
Fig. 14
Drill two holes (D) Æ 10 in the lintel or in the ceiling, 74 mm to the
right and to the left of the centre of the door (C).
25/56