SPECIAL WARNINGS FOR THE METERING OF SULPHURIC ACID (MAX. 50%)
In this case it is essential to bear in mind the following:
If the equipment is not attached to the system you can carry out this operation, by activating the pump for a few seconds
(15-30) holding it upside down with no tubes connected to the fittings, if that is not possible then disassemble and reassemble
the pump body (Fig .10), via the four fixing screws.
OPERATIONAL INSTRUCTIONS (COMMISSIONING)
Control Panel
1
Start and Stop Button
2
Button to scroll the menu to the right, increase values
3
Button to scroll through the menus to the left, decrease values
4
Button access to submenus, scroll down the menu below, to CONFIRM your choice
5
Button to scroll up the submenu
6
Yellow LED flow status alarm / power failure alarm / maximum acceptable impulse difference alarm
7
Injections signalling red LED
8
Bi-colour LED pump powered / Stand by
9
Graphic Display
Multifunction pump
The metering pump can operate in either Proportional or manual mode. At the first power on you can choose the
operating configuration of the equipment. With reference to the following table, the operator can select the mode that best
suits his metering needs: only some of the many programming menus will be made available, so you get a simplification and
speeding up of the device commissioning.
Configuration
VFT
VFT-S
MF
VFT-T
VFT-S-T
MF-T
ENGLISH
42
replace the transparent PVC suction hose with a semi-rigid polyethylene delivery tube.
•
remove in advance all the water present in the pump body, in fact if this is mixed with the sulphuric acid it
•
generates a strong concentration of gas resulting in the overheating of the area causing damage to the valves
and the pump body.
Type
FW01
FW02
FW03
FW05
FW06
FW07
Fig. 8 – Control and Display Panel
Operating functions: