Accessory Water Supply (AWS)
The connection to the local water line network
must take place via a specialist, e.g. a certified
plumber. (Please comply with the regulations of
the local water supply company). A return flow
stop may be recommendable. The automatic
water supply takes place controlled by a soleno-
id valve (water inlet). The unit comes standardi-
zed with the water supply set automatically on a
max. of 12 liters. This means that after the fill
level has reached 12 liters, the water supply
shuts off. The controlling of the water supply
takes place via the electrode bars of the water
level indicator. For a perfect functioning of the
automatic water supply, the electrode bars must
be cleaned regularly with a sponge to free them
from lime and dirt deposits.
Water faucet
Gasket
Membrane
Valve
Gasket
in Place
Safety
Pressure
Hose
Accessories: Water guard
with valve 220-240V 3/4"
Water supply hose for unit 3/4"
Disconnect the mains plug before opening the equipment!
Power outlet (socket)
Schuko
Adapter
Plug
Acoustic
Alarm
Operating
Power Plug
Indicator
Humidifier
Sensor - position
horizontally onto
the ground
R e p a i r a n d M a i n t e n a n c e
To guarantee an optimal functioning and a long
lifetime of your B 300 unit, repair and mainten-
ance are inevitable. Depending on the conditions
in the room environment, (air and water quality),
the need for repair and maintenance can differ
(see the table maintenance intervals). The requi-
red works are described systematically in the fol-
lowing chapter.
For all works on the unit, always unplug the
humidifier or otherwise make sure that
power to the unit is off!
O p e n i n g t h e C a s i n g
To perform various maintenance works, first the
casing must be opened. Although the unit does
provide for an automatic switch-off, when the
casing is opened, to insure safety, the power
should be turned off and/or the power supply
should be pulled.
For the opening of the casing, remove the lock
clips at the upper and lower side of the humidi-
fier. Now the two halves of the casing can be pul-
led open in both arrow directions (see picture
below). Handle the casing parts with care so that
they are not damaged.
Now you can also remove the technical module. To
remove the module, lift it completely upwards. For
reinserting the technical module, slide it into the
unit along the on the bottom of the water reservoir
located gliding mechanism. Attention: check the
tension of the blue vapor filter; it can increase
during the procedure. The tension can be increased
prior to the maintenance procedure by means of the
tension pulley delivered with the unit.
The reassembling takes place in reverse order. First
slide one half of the casing on the water reservoir
up to the center of the unit. Afterwards the second
half of the casing is assembled likewise onto the tub
and pushed toward the center.