E r r o r C o r r e c t i o n
Error
Not functioning at all
(no STANDBY indicator)
No Function (STANDBY -
Symbol blinks)
Water level indicator
missing
Unit runs, but vapor
filter does not move
Unit leaks water
Automatic water supply
runs uninterrupted
Water guard gives
acoustic signal
Disconnect the mains plug before opening the equipment!
Cause
Unit not connected to
power supply
Fine-fuse of the circuit
board blownnnt
Reed switch
deactivated unit
Water level too low
Copper electrodes dirty
Softenend water
has been used
Tension
too low
Vapor filter rubs against
casing
Check water reservoir for
damages
Water inlet valve (soleno-
id valve) does not close
Water leaks
Solution
Check power input
Replace fine-fuse of the
circuit board
Check casing that it is
completely locked
refill water
Clean
copper electrodes
Use ordinary tab water
Increase tension, see
„Changing of Filters"
If still too low, replace
vapor filter.
Possibly exchange driving
roller.
Increase tension see „Changing
of Filters" If still too low, replace
Replace water reservoir
Dirt residue in the
water feed tube
Check Electrodes
for pollutants
Replace solenoid valve
check water quality
Check for the cause. Cut off
supply for water guard from
the net for some seconds