Télécharger Imprimer la page

Condair Brune B 300 Manuel D'instruction page 16

Publicité

Les langues disponibles

Les langues disponibles

Now you can snap the lock clips. Make sure that all
lock clips are locked securely.
Attention: When mounting the casing half, it is
important that the orientation is followed correctly.
See the recess for the power cable.
C h a n g i n g t h e F i l t e r s
Air cleaning filter
To change the air-cleaning filter, the casing has
to be opened first (for instructions see the chap-
ter about Opening the Casing). Now the air-clea-
ning filter can be removed by hand from its posi-
tion. It is important that no residue remain.
Once the old filter is completely removed, the
new filter (Art. No. 6361) can be inserted.
Position the new filter into the same place as the
old one. It is important that filter does not inter-
fere with the rotor blades of the fan. In addition,
the filter edges should not extend outward.
Vapor Filter
For a comfortable changing of the filter, we
recommend to keep the water level as low as
possible.
First, open the casing (for instructions see the
chapter about Opening the Casing (p.15)).
The old vapor filter can now be removed in that
you either open or cut the zipper. Remove the fil-
ter completely. Check the water reservoir for any
residue, and if present remove it. Dispose of the
Double-sided
old filter fleece into the residual waste.
air flow
Now remove the tension pulley (see illustration).
You can now start with the inserting of the new
filter (Art. No. 6360) as shown on the picture.
Close the zipper and check the tension. If it is
sufficient, you can close the casing as described
in the previous chapter. If the tension is not suf-
ficient, insert the tension pulley and repeat the
process as described above.
If the tension pulley is loaded, remove it.
16