Changing of the UVC Lamp
The change of the UV lamp should take place via
authorized technical personnel. For all work on the
unit pull the power supply plugs or ensure that the
power is disconnected! For changing the UVC lamp,
the casing is opened as described before and the
technical unit is taken out of the water tank.
Afterwards the cover of the technical unit is unscr-
ewed and the screws at the bulb socket of the UV
lamp are removed. Now the UV lamp can be pulled
out to the rear. Pull the defective lamp from its
socket and insert the new UVC lamp (Art. No.:
6210). Afterwards you push the lamp back again
into the UVC protecting glass (Art. No. 6212), Fit
the socket with the existing screws and close the
cover of the technical unit. Please also examine the
surrounding parts during the exchange of the UVC
lamp such as the UV protecting glass and the seal
(Art. No. 6213) of the UVC lamp. If you should
determine damages, the unit may be operated again
only after having exchanged the defective part.
Please dispose the defective UVC lamp in the same
manner as fluorescent tubes according to the spe-
cific local regulations of your domicile.
Disconnect the mains plug before opening the equipment!
Cleaning of your Humidifier B 300
Every 3-4 months the unit should be cleaned
from lime arrears and contamination (dependent
on the site conditions: Water hardness dusty con-
dition air quality). For this procedure, the casing
is opened as in picture ".." (See also chapter on
Opening the Casing). The cleaning can be accom-
plished with commercial cleaning agents. Do not
use benzene or other solvents that can damage
plastics! To remove lime residues please use the
lime remover of the brand Brune (Art. No. 9016)
or a commercial lime remover. All cleaning agent
residues must be completely removed (rinse well
with clear water), since otherwise a foaming of
the cleaning agents can damage the unit.
If the unit is not operated for a longer time, the
residual water is to be emptied and the tension of
the vapor filter is to be decreased (see the chap-
ter
on
Changing
Additionally, the unit should be cleaned.
A basic cleaning should take place annually (pos-
sibly by our maintenance service).
Adjusting the humidity indicator
An authorized specialist should perform the
adjustment. The Humidifier B 300 offers the pos-
sibility to adjust the indication of the relative
humidity within a range of +/- 5% of the actual
value, and thereby to adapt the display to other
devices or measures. Please note that there is a
microclimate in each zone of a room area and
therefore the different value displayed from one
unit to another unit or appliance, is possible and
correct. For adjustment/calibration, proceed as
follows:
opening the casing as described in the section
„opening the casing" (p.15)
with a small screwdriver, carefully turn the
adjustment pot (potentiometer). It is located
underneath the circuit board and is accessible
by a hole in the casing at the operating panel.
You should make the adjustment in several
steps, i.e. make only a small turn at the poten-
tiometer, and check the result at the display. If
the desired result should not be reached yet,
turn again carefully at the potentiometer.
Close casing after adjustment.
Vapor
Filter
(p.16)).