5.4.1 ON/OFF Boost
Setup Operation Boost
The BOOST function enables a faster charge of the batteries. This function is timed controlled and is
automatically switched off when the battery is fully charged : BOOST stops when batteries current < 20% of
charger rated current. BOOST function can also be disabled by either a DIP switch (E) inside the battery charger
or the BOOST press-button into Operation menu.
5.4.2 ON/OFF charger output
Setup Operation Charge
Indication if charge is ON or OFF
5.4.3 Input current 6A
Setup Operation Input current 6A
5.4.4 Current limit
Setup Operation Current limit
The remote display has the ability to limit the total output battery charger current from 100% to 30% rated
output current. When activated, this limits runs during 8 hours before coming back to rated value.
At 230Vac ±15% input, this mode
limits the charger's output power in
order to ensure the input current us
below 6A. This may prevent the
circuit breaker from tripping.
1 : Input current limit under
1
operation
This function enables the user :
-
To lower the charge current if required ;
-
To control the input power consumption
of the battery charger in case of dips or
overcurrent nuisance tripping on AC
network due to an excessive consumption
on the boat overall electrical network.
1
1 : Current limit under operation
26