The icon shows status for digital input and output
The icon gives access to a status image. It is not possible to manually ad-
just the status of the digital inputs and outputs.
The screen on the left shows the status screen for the blower setup, where
1 set point is selected.
The top 6 icons show the digital outputs:
0
ON The blower is running
OFF The blower is stopped
1
ON Indicates a fault in the blower
OFF here is no fault in the blower
2
ON External electric motor 1 running
OFF External electric motor 1 stopped
3
ON External electric motor 2 running
OFF External electric motor 2 stopped
4
ON External heating element - not available
OFF External heating element - not available
5
ON Vibration sensor - not available
OFF Vibration sensor - not available
The bottom 8 icons show the digital inputs:
0
ON Starts the blower
OFF Stops the blower
1
ON Starts the blower with a short pulse
OFF If the blower starts with a pulse, it continues to run
2
ON Allows the blower to start
OFF Stops the blower
3
ON Reduces set point
4
ON Increases set point
5
ON Select setpoint 1 at 2 or 3 fixed setpoints
6
ON Select setpoint 2 at 2 or 3 fixed setpoints
7
ON Select setpoint 3 at 3 fixed setpoints
The screen on the left shows the blower setup, where more than one set
point is selected.
The bottom 3 icons on the right show the digital inputs that select, which set
point should be active. Here, set point 1 is active.
The icon for blower setup - setup wizard
The icon indicates a wizard that makes it easy to set up the blower. Select-
ing this wizard gives you access to:
•
set point setup
•
setting up air velocity
•
startup sequence setup
•
stop sequence setup
•
setting up user rights
23