The icon gives access to the blower start and stop sequence
The blower control can start and stop up to 2 external electric motors, in
connection with starting and stopping the blower. It is possible to select the
order of both start / stop of blower / electric motors, and with which time
interval, the blower and each of the two electric motors must start or stop,
respectively.
The screen on the left shows an example where:
When the blower receives the start signal at time 0, the external electric
motor 1 is started (on a cutter, for example).
10 sec. after the start signal, the blower itself is started.
20 sec. after the start signal, the external electric motor 2 is started (on
a separator, for example).
Times 10 and 20 sec. are examples only.
The screen on the left shows the default settings for the start sequence.
There are no external electric motors connected to the blower, and the blow-
er starts when it receives the start signal.
When the menu for the blower's start sequence is left with the return but-
ton, you come to a corresponding stop sequence menu. The screen on the
left shows the default stop sequence. The stop sequence can be set in the
same way as the start sequence.
Pressing the icon Wire diagram, a diagram appears, showing the connec-
tion of the digital inputs and outputs.
If nothing is set in the stop sequence, all external motors will stop when the
blower is stopped.
When the start/stop sequence is in progress, the blower icon flashes green
during start and red during stop.