6.2 | Error messages
7 | Features
• Reverse polarity protected, short-circuit-proof and
• Trickle charging and overload protection
• Pre-charge function for deeply discharged batteries
• Battery test function, fault detection
• For (all) lithium-ion starter batteries
• Max. charging current 1 A (automatic adjustment,
• 8 LED displays
• 7-stage charging process
• Operating voltage: 220 - 240 V/AC (50/60 Hz)
• Ambient temperature: -15°C to +45°C
0020145_ProCharger_Lithium_ANL_18.indd 41
7. "Error" LED flashes: The voltage of the connected
battery is higher than 14.3 V.
8. "Faulty" LED: Once charged, the battery is unable to
store the energy on a long-term basis.
9. "Wrong polarity" LED: The battery terminals have been
connected the wrong way round.
10. "Error" LED and "Pre-charging" LED flash: A deep-
+
discharged battery could not reach a voltage
of 4 V within 24 hours.
spark-free when connecting
I/U charge characteristic)
The battery charger is designed for an operating temperature
of -15°C to +45°C. For the permissible temperature range for
charging the battery refer to the specifications of the battery
manufacturer.