Partial opening stroke length (PAR) expressed as a percentage
of the total stroke.
NOTE: only the leaf relating to motor M1 opens
Automatic re-closing time from partial opening PAR (0 = off)
Determines the behaviour of the FLASH output
0 = output always active (not flashing) during the opening and
closing manoeuvre
1 = output flashing during the opening and closing manoeuvre
Determines the pre-flashing modes of the FLASH output
(inactive is
= 0)
0 = pre-flashing before each opening and closing manoeuvre
1 = pre-flashing before each closing manoeuvre
2 = pre-flashing before each opening manoeuvre
Determines the duration of the pre-flashing (0 = off)
Courtesy light configuration
0 = on during manoeuvre and, at the end of the manoeuvre for
the time indicated by
1= on if the gate is not closed and for the time indicated by
with the gate closed.
2 = on for the time indicated by TIME LIGHT after every
command (OPEN, CLOSE, PAR, SBS)
Courtesy light ON time.
NOTE: the courtesy light can also be switched on and off
from the radio remote control; if it is switched on from the
radio remote control, it can be switched off only from the radio
remote control.
Enables the "man present" function on the SBS, PAR, OPEN
and CLOSE inputs
WARNING
by enabling the operation of the radio remote
controls, it is inhibited
Determines the operation of the IND/ELEC output
0 = off
1 = open gate indicator light active if the gate is not closed
2 = proportional open gate indicator light
- Slow flashing during opening
- Fast flashing during closing
- Two flashes + pause if stopped not closed
3 = electric lock
4 = magnetic lock, output active if gate is closed.
WARNING
Interface the magnetic lock with a relay with a
24VDC coil and set
Specify the number of manoeuvres before the maintenance
request signal.
NOTE: the signal uses the FLASH output; if closed, it flashes
continuously
Enables the maintenance request signal
0 = inactive
1 = active
Electric lock activation time or magnetic lock deactivation time.
Water hammer during opening (0 = off).
When closed, before opening it pushes it closed; this facilitates
the release of the electric lock
Water hammer during closing (0 = off).
At the end of the closing manoeuvre, the motor is kept active
for the set time; this facilitates the locking of the electric lock.
≠ 0.
50
0
100
0
0
900
1
0
1
0
0
2
0
0
20
0
0
2
0
0
900
0
0
1
0
0
4
X1000
10
0
200
0
0
1
2
1
10
0
0
100
100 ms
0
0
100
100 ms
%
s
s
s
cicli
s