2.6 - List of cables required
The following table indicates the cables required for the connections
of the various devices in a typical system.
The cables must be suitable for the type of installation; for example,
ELECTRIC CABLE TECHNICAL SPECIFICATIONS
CONNECTION
Control unit power transformer input
Flashing light (FLASH)
Courtesy light (LED)
Antenna
Electric lock (IND/ELEC)
Photocells (transmitter)
Photocells (receiver)
Safety edge
Key switxh
Motor power supply (M1 and M2)
Encoder cables
3 - PRELIMINARY CHECKS
Before installing this product, verify and check the following steps:
- Check that the gate or door are suitable for automation
- The weight and size of the gate or door must be within the
maximum permissible operating limits
- Check the presence and strength of the security mechanical
stops of the gate or door
- Check that the mounting area of the product is not subject to
flooding
- Conditions of high acidity or salinity or proximity to heat sources
could cause malfunction of the product
- Extreme weather conditions (for example the presence of snow,
ice, high temperature range, high temperatures) may increase
the friction and therefore the force required for the handling and
4 - PRODUCT INSTALLATION
4.1 - Installation
WARNING
The installer must verify that the working
temperature range stated on the automation device is suitable for
the location where it is installed.
The automation system must be equipped with
WARNING
a pressure-sensitive edge protecting all possible crushing points
(hands, feet, etc.) in accordance with the requirements of the EN
13241-1 standard.
The gate must have limit stops in the open
WARNING
and closed positions which prevent it from travelling over the
permitted limits.
a H03VV-F type cable is recommended for indoor installation or a
H05RN-F/H07RN-F cable is recommended for outdoor installation.
CABLE
3 x 1,5 mm²
3 x 2,5 mm²
3 x 0,55 mm²
Cavo RG58
2 x 1,5 mm²
2 x 0,55 mm²
4 x 0,55 mm²
2 x 0,55 mm²
4 x 0,55 mm²
2 x 1,5 mm²
4 x 0,55 mm²
initial starting point may be higher than under normal conditions.
- Check that the manual operation of gate or door is smooth and
friction-free and there is no risk of derailment of the same
- Check that the gate or door are in equilibrium and stationary if
left in any position
- Check that the power line to supply the product is equipped with
proper grounding safety and protected by a magnetothermal and
differential security device
- Provide the power system with a disconnecting device with a
gap of contacts enabling full disconnection under the conditions
dictated by the overvoltage category III.
- Ensure that all materials used for the installation comply with
current regulations
Before proceeding with the installation, check the integrity of the
product and that all components are present in the package (Fig. 3).
Also check that the gearmotor's installation zone is compatible with
its overall dimensions (Fig.1).
Check the opening angle permitted by the bracket fixing points
using the graph in Fig.4 for inward opening. For outward opening,
refer to the graph in Fig.4.1.
Fig.6 shows a typical installation: Gear motors (1) - Photocells (2)
- Columns for photocells (3) - Flashing light with antenna (4) - Key
switch or digital keypad (5) - Control unit (6) - Pressure-sensitive
edge (7)
MAXIMUM PERMITTED LIMIT
if less than or equal to 20 m
if greater than 20m (connect the earth
wire close to the control unit)
20 m
10 m (recommended < 5 m)
10 m
20 m
20 m
20 m
20 m
10 m
10 m
EN
31