Determines the operating mode of the step-by-step control
(SBS)
0 = normal AP-ST-CH-ST-AP-ST...
1 = alternating STOP AP-ST-CH-AP-ST-CH...
2 = alternating AP-CH-AP-CH...
3 = condominium mode 1; from open position, the
8
NOTE: closing does not occur if
4 = condominium mode 2; a SBS command carries out
9
M2 leaf delay during opening
Low-speed stroke width (slow-down phase) both during
10
opening and closing
P = custom (see paragraph 4.12.2)
Determines the behaviour of the control unit when it is
switched on
11
0 = no action
1 = executes, if possible, the closing command
If active, in the closed position, it disables the power supply to
12
PHPOW
13
Number of leaves of the system
4.17 - Advanced Parameters
PARAMETERS
Determines the behaviour of the automation, starting from the
closed position
1
0 = if PH1 is engaged, no opening command is executed
1 = if PH1 is engaged, the opening command is executed
Verification of the engaged state of PH2
0 = active both during the opening manoeuvre and the closing
2
1 = active only during the opening manoeuvre
Photocell functionality test
0 = no test
1 = checks the functionality of the photocells connected to
3
2 = checks the functionality of the photocells connected to
3 = checks the functionality of the photocells connected to
Determines the type of safety edge connected to the STOP/
EDGE terminals
4
0 = NC contact STOP
1 = 8k2 safety edge
2 = NC sensitive edge
Determines in which situations the triggering of the safety edge
connected to the STOP/EDGE inputs must be assessed
0 = status of the STOP/EDGE input assessed
5
1 = triggered both during opening and closing
2 = triggered both during opening and closing
Safety edge test
6
0 = inactive
1 = active
closing manoeuvre starts when the automatic re-closing
timer expires
the closing manoeuvre only if the leaf is in the open
position.
DESCRIPTION
manoeuvre
terminal PH1
terminal PH2
terminals PH1 and PH2
only during the closing manoeuvre, the triggering involves a
full opening manoeuvre
by stopping the automation and reversing the direction of
travel for about 2 seconds
by stopping the automation and reversing the direction of
travel for about 0.5 seconds
0
= 0
2
20
0
0
2
DEFAULT
1
0
0
0
0
0
EN
0
4
0
300
0
100
%
0
1
0
1
1
2
MIN
MAX
UNIT
0
1
0
1
0
3
0
2
0
2
0
1
41