4.10 - Deactivation of safety devices
EDGE
The control unit provides for (default setting) the installation of a
safety edge connected to the STOP/EDGE inputs. In the event of
a missing or incorrect connection, the operation of the automation
is inhibited.
In the case of a system in which the installation of a safety edge is
not envisaged, it is possible to disable its use by setting the EDGE
dip switch to the ON position.
CONFIRM THE DESIRE TO DISABLE THE
WARNING
SAFETY EDGE BY PRESSING AND HOLDING BUTTONS
and
UNTIL THE EDGE LED FLASHES.
PHOTO 2
The control unit provides for (default setting) the installation of one
or more photocells connected to the PH2 input. In the event of a
missing or incorrect connection, the operation of the automation is
inhibited. In the case of a system in which the installation of PH2
is not envisaged, it is possible to disable its use by setting the PH2
dip switch to the ON position.
4.11 - Display during normal operation
When it is switched on for the first time, the control unit shows a scrol-
ling text on the display indicating: board model, firmware version and
serial number, and the last piece of information is
indicating that the motor type must be selected to start configuring the
system.
To select the motor type, scroll through the list with the UP
DOWN keys
; at the motor concerned, press and hold the MENU
MESSAGES
MEANING
Auto-learning of gate leaf stroke not carried out: carry out the auto-learning procedure
Gate closed, control unit restarted
The gate is opening
The gate is closing
The gate was stopped during the opening manoeuvre
The gate was stopped during the closing manoeuvre
PH1 triggered (photocell 1)
PH2 triggered (photocell 2)
The automation is carrying out the realignment procedure
Gate open, automatic re-closing timer not active
The gate is performing partial opening
The gate is stopped in the partial opening position
The gate has reached the open position and automatic re-closing is active; the flashing dash indicates that the
countdown is active. During the last ten seconds, the seconds remaining until re-closing are indicated
The gate has been opened with the PAR control and the automatic re-closing timer from partial opening is active;
during the last ten seconds, the seconds remaining until re-closing are indicated
Auto-learning procedure blocked due to the triggering of the safety devices or an intentional stop
Leaf 1 opening stroke auto-learning
Leaf 2 opening stroke auto-learning
Leaf 1 closing stroke auto-learning
Leaf 2 closing stroke auto-learning
Customised auto-learning of slow-down point during leaf 1 opening
Customised auto-learning of slow-down point during leaf 2 opening
Customised auto-learning of slow-down point during leaf 1 closing
Customised auto-learning of slow-down point during leaf 2 closing
WARNING
CONFIRM THE DESIRE TO DISABLE PH2
BY PRESSING AND HOLDING BUTTONS
THE PH2 LED FLASHES.
PHOTO 1
The control unit provides for (default setting) the installation of one
or more photocells connected to the PH1 input.
In the event of a missing or incorrect connection, the operation of
the automation is inhibited.
In the case of a system in which the installation of PH1 is not envis-
aged, it is possible to disable its use by setting the PH1 dip switch
to the ON position.
WARNING
CONFIRM THE DESIRE TO DISABLE PH1 BY
PRESSING AND HOLDING BUTTONS
PH1 LED FLASHES.
key
until
appears on the display.
WARNING
The ADVANCED PARAMETERS table shows the
correspondence between the motor model and the numbers on
the display.
The following table indicates the messages shown on the display
and
during normal operation of the automation:
EN
and
UNTIL
and
UNTIL THE
35