ELECTRICAL CONNECTIONS FOR PHOTO1 PHOTO2
SAFETY AND CONTROL DEVICE CONNECTORS
24 VAC
Accessories 24VAC power supply unregulated 200mA MAX; not active during battery operation
24 VAC
COM
Positive common outputs FLASH - IND/ELEC – LED and accessories
IND, open gate indicator light output, 24VDC 5W MAX
IND/ELEC
ELEC, electric lock output 12VDC 15VA MAX
selectable with the
LED
Courtesy light output, 24VDC unregulated 15W MAX also controllable via radio remote control
NEG
Accessories power supply negative
Photocells PH1 and PH2 power supply positive;
PH-POW
operating mode configurable with the
STOP/EDGE
8k2 contact/safety edge NC input, operating mode configurable with the
STOP/EDGE
WARNING
PH2 opening photocell NC input; at any time during opening/closing, the triggering of the photocell (contact opening)
blocks the movements immediately. When the contact is closed again, the opening operation is restored. The operat-
PH2
ing modes can be configured with the
WARNING
PH1 closing photocell NC input; at any time during closing, the triggering of the photocell (contact opening) blocks and
reverses the direction of travel. As long as PH1 is triggered, it is not possible to close the gate. The operating modes
PH1
can be configured with the
WARNING
OPEN
OPENING control NO input, MAN PRESENT function configurable with the
CLOSE
PARTIAL OPENING control NO input; with the
PAR
second safety edge;
MAN PRESENT function configurable with the
STEP-BY-STEP (SBS) control NO input; with each activation, the AP (open) - ST (stop) - CH (close) commands are
SBS
carried out in succession; the operating modes can be configured with the SBS SETUP parameter.
MAN PRESENT function configurable with the
COM
PH2, PH1, OPEN, CLOSE, PAR, SBS inputs common positive
SHIELD
Antenna - shield
ANT
Antenna - signal
34
PH2
PH2
TX
RX
1
2
parameter
with the
dip switch in the ON position, the input is always disabled
with the PH2 dip switch in the ON position, the input is always disabled
with the PH1 dip switch in the ON position, the input is always disabled
CLOSING control NO input, MAN PRESENT function configurable with the
M2
PH1
TX
1
2
parameter
parameter
parameter
parameter, the input can be optionally configured as a
parameter
parameter
PH1
RX
parameter
parameter
parameter