Use the following procedures to operate the Glo-Ray
Series Mini-Merchandisers.
WARNING
Read all safety messages in the IMPORTANT SAFETY
INFORMATION section before operating this equipment.
Startup
Perform the following step for startup of all GRHW models and
then proceed to the appropriate section for the remaining steps
for startup.
1. Plug unit into a properly grounded electrical receptacle of
the correct voltage, size and plug configuration. See the
SPECIFICATIONS section for details.
GRHW-1P, -2P, -1SG, and -1SGS
1. Move the Power I/O (on/off) switch on the base to the I
(on) position. The base heat control will energize and the
overhead lights will turn on.
2. Turn the base heat control to the desired temperature
setting. The base temperature range is from 82°F to 200°F
(28°C to 93°C).
Power I/O
(on/off) Switch
Base controls for GRHW-1P, -2P, -1SG, and -1SGS
3. If the unit is equipped with a Power I/O (on/off) toggle switch
or an overhead heat control in the upper housing, move the
switch to the I (on) position or turn the control to the desired
setting. The overhead heating element will energize.
4. If the unit is equipped with both a Power I/O (on/off)) toggle
switch and an overhead heat control in the upper housing:
• Move the Power I/O toggle switch to the I (on) position.
The overhead lights will turn on.
• Turn the overhead heat control to the desired setting.
The overhead heating element will energize.
Overhead
Heat Control
(optional)
Top controls for GRHW-1P, -2P, -1SG, and -1SGS
Form No. GRHWM-0520
GRHW
®
Base Heat
Control
Power I/O (on/off)
Toggle Switch
GRHW-1SGD and GRHW-1SGDS
1. Move the Power I/O (on/off) switch to the I (on) position.
• The overhead lights will turn on, the overhead heating
element will turn on, the heated glass shelf will energize,
and the base heating element will energize.
2. Turn the base heat control to the desired temperature
setting.
3. Turn the glass shelf heat control to the desired setting.
Ground Fault
Circuit Interrupter
(GFCI)
Power I/O
(on/off) Switch
Controls for GRHW-1SGD and GRHW-1SGDS
(GRHW-1SDS controls shown)
Shutdown
GRHW-1P, -2P, -1SG, and -1SGS
1. Move the Power I/O (on/off) switch on the base to the O
(off) position. The overhead lights and heated base will
shut off.
2. If the unit is equipped with a Power I/O (on/off) toggle
switch or an overhead heat control in the upper housing,
move the switch to the O (off) position or turn the control
to the OFF (O) position. The overhead heating element will
shut off.
3. If the unit is equipped with both a Power I/O (on/off) toggle
switch and an overhead heat control in the upper housing:
• Move the Power I/O toggle switch to the O (off) position.
The overhead lights will turn on.
• Turn the overhead heat control to the OFF (O) position.
The overhead heating element will shut off.
GRHW-1SGD and GRHW-1SGDS
1. Move the Power I/O (on/off) switch to the O (off) position.
The overhead lights, overhead heating element, heated
glass shelf, and heated base will shut off.
NOTE: Refer to the MAINTENANCE section for Ground Fault
Circuit Interrupt (GFCI) switch information.
9

OPERATION

Glass Shelf
Heat Control
Base Heat
Control