Télécharger Imprimer la page

Scheppach C-BSB74/1BE-X Traduction Du Mode D'emploi Original page 25

Publicité

Les langues disponibles

Les langues disponibles

Safety instructions for drills
1) Safety instructions for all work
a) When performing work during which the tool at-
tachment or the screws can meet with con-
cealed power lines or its own connection cable,
hold the electric tool by the insulated gripping
surfaces. Contact with a live wire may make ex-
posed metal parts of the power tool live and could
give the operator an electric shock.
2) Safety instructions when using a long drill
a) Never work at a speed that is higher than the
maximum permissible speed for the drill. At
higher speeds, the drill can easily twist if it is able to
turn freely without contact with the workpiece, and
cause injuries.
b) Always start drilling at a lower speed and once
contact has been established between the drill
and the workpiece. At higher speeds, the drill can
easily twist if it is able to turn freely without contact
with the workpiece, and cause injuries
c) Never apply excessive pressure and only in the
longitudinal direction to the drill. Drills can twist
and this can cause the drill to break, or lead to a
loss of control and to injuries.
Residual risks
The product has been built according to state-of-
the-art and the recognised technical safety rules.
However, individual residual risks can arise during
operation.
• Damage to hearing if the stipulated hearing protec-
tion is not worn.
• Residual risks can be minimised if the "Safety In-
structions" and the "Intended Use" together with the
operating manual as a whole are observed.
• Use the product in the way that is recommended in
this operating manual. This is how to ensure that
your product provides optimum performance.
• Furthermore, despite all precautions having been
met, some non-obvious residual risks may still re-
main.
WARNING
This power tool generates an electromagnetic field
during operation. This field can impair active or pas-
sive medical implants under certain circumstances. In
order to prevent the risk of serious or deadly injuries,
we recommend that persons with medical implants
consult with their physician and the manufacturer of
the medical implant prior to operating the power tool.
WARNING
In case of extended working periods, the operating
personnel may suffer circulatory disturbances in their
hands (vibration white finger) due to vibrations.
Raynaud's syndrome is a vascular disease that caus-
es the small blood vessels on the fingers and toes to
cramp in spasms. The affected areas are no longer
supplied with sufficient blood and therefore appear
extremely pale. The frequent use of vibrating prod-
ucts can cause nerve damage in people whose circu-
lation is impaired (e.g. smokers, diabetics).
If you notice unusual adverse effects, stop working
immediately and seek medical advice.
ATTENTION
The product is part of the 20V IXES series and may
only be operated with batteries of this series. Batter-
ies may only be charged with battery chargers of this
series. Observe the manufacturer's instructions.
WARNING
Follow the safety and charging instructions
and correct usage given in the instruction
manual of your 20V IXES Series battery and
charger. A detailed description of the
charging process and further information
are provided in this separate manual.
6
Technical data
Cordless drill
Engine voltage
Idle speeds n
• Gear 1
• Gear 2
Max. torque
Chuck span Ø
Weight (without battery)
Drilling diameter for wood
Drilling diameter for steel
Protection category
Temperature
• Operation
• Storage
Battery charger
Input
Rated voltage
www.scheppach.com
C-BSB74/1BE-X
0
20 V
0 - 400 rpm
0 - 1550 rpm
50 Nm
1.5 - 13 mm
1.2 kg
max. 30 mm
max. 13 mm
IPX0
max. 50°C
-20 – 50°C
5 – 30°C
SBC2.4A
230 – 240 V~
50 Hz
GB | 25

Publicité

loading

Ce manuel est également adapté pour:

58093029944