Troubleshooting
8. Fold the chemical protective suit away from the wearer in
such a way that no chemicals or cleaning agents can enter
the interior of the suit.
9. Climb out of the safety boots and trouser legs.
Dräger recommends logging the application (see "Test
protocol", page 41).
5
Troubleshooting
Fault
Cause
Fastener system
Foreign objects in
jammed
zipper mechanism
Excess friction
Chemical protec-
Fastener system
tion suit leaking
not closed
Suit material dam-
aged
Safety boots or
gloves faulty or
leaky joint
Valve disc or seat
dirty or faulty
Full face mask or
face cuff leaking
Chemical protec-
Valve disc on suit
tive suit not venti-
valve sticks
lated
Adhesive tape
Velcro tape is
becomes detached
attached with
adhesive. Clean-
ing and decontami-
nation can cause it
to become loose.
1) not part of the EU prototype tests
6
Maintenance
6.1
Maintenance table
The specified intervals are recommended by Dräger. If
required, deviating national guidelines must be observed.
For maintenance work on the full face mask, ventilation unit,
automatic switch valve and compressed air breathing
apparatus, see the relevant instructions for use.
Originally sealed chemical protective suits must only be
checked after 5 years if they were stored in the original
packaging or a CPS storage and transportation bag. After this
period or when the seal is broken, chemical protective suits
must be serviced in accordance with specified intervals.
Chemical protective suits with integrated full face mask are
not sealed as the full face mask is subject to other
maintenance intervals
30
Work to do
Chemical protective suit
visual inspection
Chemical protective suit
Cleaning and disinfecting
1)
Remedy
Maintaining the fastener sys-
Clean the zipper
tem
mechanism,
Service the face cuff
remove foreign
objects.
Check the seal on the chemical
protective suit
Lubricate zip fas-
tener with grease
Check the tightness of the suit
stick.
valves
Close the fastener
1) Applies for chemical protective suits stored in vehicles without a carry-
system completely.
Repair with suit
2) or during the incoming goods inspection of an originally sealed chemi-
repair kit. Re-
check for leaks.
Replace or seal.
Check for leaks
"Test protocol", page 41).
again.
Clean or replace.
6.2
Check for leaks
again.
Replace or seal.
The following examinations are mandatory. The chemical
Check for leaks
protective suit must be repaired or disposed of in case of
again.
defects.
Clean or replace.
– No holes, cuts or abrasions must be found on the outside
Check for leaks
again
– The seam tape must not become detached.
Re-stick adhesive
– The face cuff and full face mask must be clean.
tape. Check for
– The following parts must be undamaged:
leaks again.
– The suit valves must be free and undamaged.
– The suit material must not show any signs of wear. The
6.3
NOTICE
Risk of damaging the material!
For cleaning and disinfecting, do not use any solvents (e.g.
acetone or alcohol) or cleaning agents with scouring particles.
► Only follow the specified procedure and use the specified
ing bag. The interval can be extended to 2 years for chemical protec-
tive suits that are stored in the CPS storage and transportation bag.
cal protective suit
Dräger recommends logging all maintenance work (see
Visually inspecting the chemical
protection suit
of the chemical protective suit.
– Suit material
– Gloves
– Socks or boots
– Face cuff
– Full face mask
– Closure system and cover
coating must not become detached from the fabric.
Cleaning and disinfecting the
chemical protective suit
cleaning and disinfecting agents. Other agents, dosages
and application times may cause damage to the product.
Instructions for use
X
X
1)
X
X
X
X
1)
X
X
X
1)
X
X
X
2)
1)
X
X
X
X
2)
1)
X
X
|
Dräger CPS 7800