properly supervised. ● The room must be sufficiently
ventilated when the product is used at the same time as
other appliances that run on gas or other fuels. ● The
product must be cleaned frequently both inside and out (AT
LEAST ONCE A MONTH); always follow the instructions
given in the maintenance manual. ● Failure to comply with
the rules for product cleaning and the cleaning/replacement
of filters, may create a fire hazard. ● Flambé cooking is
strictly prohibited. ● Using a naked flame may damage the
filters and cause a fire hazard, and must therefore be
avoided under all circumstances. ● Extra care must be
taken when frying to prevent the oil from overheating and
catching fire. ● Please note! The accessible parts of the
device may become hot when the hob is switched on. ●
Please note! Do not connect the product to the mains until
the installation is complete. ● The regulations laid down by
local authorities must be strictly followed with regard to the
technical and safety measures to be adopted for fume
extraction. ● The extracted air must not be conveyed
through the same ducts used to extract the fumes
generated by the combustion of gas or other types of fuels.
● Never use the product without the grille properly
installed! ● Only use the fastening screws supplied with the
product for installation, or if not supplied, purchase the
correct type of screws. Use screws of the right length, as
indicated in the installation guide. ● When this product is
used together with other devices powered with non-
electrical energy, the negative pressure of the room must
not exceed 4 Pa (4 x 10-5 bar). ● This manual must be
stored for future consultation at any time. If sold,
transferred or moved, it must remain with the product.
● Range hoods and other cooking fume extractors may
adversely affect the safe operation of appliances burning
gas or other fuels (including those in other rooms) due to
back flow of combustion gases. These gases can
potentially result in carbon monoxide poisoning. After
installation of a range hood or other cooking fume
extractor, the operation of flued gas appliances should be
tested by a competent person to ensure that back flow of
combustion gases does not occur.
ELECTRICAL CONNECTION SAFETY
● Disconnect the product from the mains. ● The
installation must be carried out by professionally qualified
personnel with knowledge of the regulations in force for
installation and safety. ● The manufacturer disclaims all
liability for persons, animals or property if the guidelines
provided in this chapter are not followed. ● The power
cable must be long enough to allow removal of the hob
from the worktop. ● Check that the voltage on the rating
plate on the bottom of the product corresponds to that of
the domestic environment where it will be installed. ● Do
not use extension cords. ● The earth cable must be 2cm
longer than the other cables. ● If the product is not
equipped with a power cable, use one with a minimum
conductor diameter of 2.5 mm2 for power up to 5500 Watt;
for higher power levels, the diameter must be 4 mm2. ●
The temperature must not reach 50°C above room
temperature anywhere along the cable. ● The product is
intended to be permanently connected to the mains,
therefore, make the connection to the mains using an
approved omnipolar switch that guarantees complete
disconnection from the mains in category III overvoltage
conditions, and which is readily accessible after the
installation.
● Please note! The interconnection cable must be
replaced by the authorised customer service representative
or by a person with similar qualifications.
● Please note! Before reconnecting the circuit to the
mains power supply and making sure that it is working
correctly, always check that the power cable is correctly
installed.
POWER LIMITATION:
Limitation function, which allows a maximum power limit to
be set (kw)
The setting must be made when the product is connected
to the mains or when the mains power itself is restored
(within the following 2 minutes). Size the electrical system
protection according to the selected Power Limitation level.
For the Power Limitation setting sequence, see the
Operation section of this manual.
The product can also be used in
WINDOWS KIT:
conjunction with a Window sensor KIT (not supplied by
the manufacturer). If the Window sensor KIT is installed
(only if used in DUCT-OUT mode), air extraction will halt
every time the window in the room, on which the KIT is
applied, is closed. The KIT must be electrically
connected to the device by qualified and specialised
technical personnel. The KIT must be certified
separately in accordance with the safety standards for
the component and its use with the device. Installation
must be carried out in accordance with current
regulations for domestic systems.
PLEASE NOTE: the wiring of the KIT to be connected
to the product must be part of a certified safety extra-
low voltage (SELV) circuit. The manufacturer of this
device disclaims all liability for any inconvenience,
damage or fires caused by defects and/or problems
associated with the malfunction and/or incorrect
installation of the KIT.
INSTALLATION SAFETY
● The electrical and mechanical installation must be
performed by qualified personnel.
● Before starting the installation: After unpacking the
product, check that it has not been damaged during
transport and in the case of problems, contact your dealer
or Customer Service, before proceeding with the
installation; Check that the purchased product is the right
size for the installation location; Check for accessories
inside the packaging (placed there for ease of transport,
such as bags containing screws, the warranty certificate,
etc.). Remove and keep them safe; Also check that there is
a power socket near the installation area
● Preparing the cabinet for installation:
• The product cannot be installed above cooling
appliances,
dishwashers,
15
the product is equipped with a Power
heaters,
ovens,
washing