Télécharger Imprimer la page

Miele PWM 509 Mode D'emploi page 131

Publicité

Fire brigade programme overview
These programmes are suitable for washing and proofing Nomex fire-fighting apparel, jack-
ets and trousers, breathing masks and chemical protective suits.
Protective clothing programmes
Protective clothing
Fabric
Programme se-
quence
Extras
Protective cloth. + proof
Fabric
Programme se-
quence
Extras
Proof protect. clothing
Fabric
Programme se-
quence
Extras
Protective clothing load size
Model
PWM 509
PWM 511
60 °C (Cold to 60 °C)
Nomex fire-fighting apparel, jackets, trousers
Pre-cleaning up to 40 °C
Main wash up to 60 °C, wash time 6 min
3 rinse cycles, Final spin
Soak, Water plus, Intensive, Rinse plus, Fill stop, Rinse
hold
60 °C (Cold to 60 °C)
Nomex fire-fighting apparel, jackets, trousers
Pre-cleaning up to 40 °C
Main wash up to 60 °C, wash time 6 min
3 rinse cycles
Proofing bath 40 °C
Final spin
Soak, Water plus, Intensive, Rinse plus, Fill stop, Rinse
hold
40 °C
Nomex fire-fighting apparel, jackets, trousers
1 rinsing bath
Proofing bath 40 °C
Final spin
Soak, Water plus, Intensive, Rinse plus, Fill stop, Rinse
hold
Quantity
1 suit (or 1–2 jackets)
1–2 suits (2 jackets)
en - Programme summary
Load ratio/Load size
clothing load size"
See
"Protective
chart
131

Publicité

loading

Ce manuel est également adapté pour:

Pwm 511