All the devices present on the airwaves are not displayed on this page but only the devices that have been associated with our
network. Seeing only the devices in your own network allows the operation of several similar networks existing within the radius
of action of the wireless without creating ambiguity; in this way the user does not see the elements that do not belong to his
pumping system.
From this menu page it is possible to associate and disassociate an element from your personal wireless network. When the machine
starts the AS menu item does not show any connection because no device is associated. In these conditions the message "No Dev" is
shown and the COMM led is off. Only an action by the operator can allow devices to be added or removed with the operations of
association and disassociation.
Association of devices
Once on the AS page, pressing
a flashing of the COMM led at regular intervals. As soon as two machines in a working communication range are put into this status, if
possible, they are associated with each other. If the association is not possible for one or both machines, the procedure ends and a
pop-up appears on each machine saying "association not possible". An association may not be possible because the device you are
trying to associate is already present in the maximum number or because the device to be associated is not recognised. In the last case
repeat the procedure from the start. The search status for association remains active until the device to be associated is detected
(irrespective of the result of association); if no device can be seen within the space of 1 minute, the machine automatically leaves
association status. You can leave the search status for wireless association at any time by pressing
procedure, a short-cut has been created that makes it possible to put the pump in association from the main page by pressing the
key.
IMPORTANT: Once the association has been made between 2 or more devices, a pop-up appears on the display asking you to extend
the configuration. This happens in the case where the devices have different configuration parameters (e.g. setpoint SP, RP etc.).
Pressing
on a pump extends the configuration of that pump to the other associated pumps. When the
ups appear with the message "Wait...", and when this message is finished the pumps will start to work regularly with the sensitive
parameters aligned; refer to paragraph 14.4.5 Parameters concerning multipump per maggiori informazioni.
Disassociation of devices
To dissociate a device belonging to an existing group, go to page AS (installer menu) of the device itself and press the
least 5 seconds. After this operation all the icons related to the connected devices will be replaced by the message "No Dev" and the
COMM LED will remain off.
Replacing devices
To replace a device in an existing group it is sufficient to dissociate the device to be replaced and to associate the new device as
described in the procedures above. If it is not possible to dissociate the element to be replaced (faulty or not available), you will have to
carry out the disassociation procedure for each device and create a new group.
PR: Remote pressure sensor
The PR parameter is used to select a remote pressure sensor.
The default setting is with no sensor present. In order to execute its intended functions, the remote sensor must be connected to a
control unit, which in turn must be associated to the esybox, see point 13.4 Operation with control unit.
As soon as a connection is established between the e.sybox and control unit and the remote pressure sensor has been connected, the
sensor starts operating. When the sensor is active, the display shows an icon of a stylised sensor with a P inside it. The remote pressure
sensor operates in synergy with the internal sensor so that the pressure never falls below the setpoint pressure in either of the two points
in the system (internal and remote sensors). This allows compensation for any pressure drops.
NOTE: in order to maintain the setpoint pressure in the point with lower pressure, the pressure in the other point may be higher than the
setpoint pressure.
T1: Low pressure delay
K
Sets the time when the inverter switches off after receiving the low pressure signal (see "Setting low pressure detection"). IThe low
pressure signal can be received on each of the 4 inputs by suitably configuring the input (see Setup of the auxiliary digitali inputs IN1,
IN2, IN3, IN4). T1 can be set between 0 and 12 s. The factory setting is 2 s.
Parameters available in version KIWA
for 5 sec puts the machine into wireless association search status, communicating this status with
:
ENGLISH
59
or
. To speed up the
key is pressed, pop-
key for at