The pump restarting pressure is linked not only to the set pressure SP but also to RP. RP expresses the decrease in
pressure, with respect to "SP" caused by the pump starting.
For example: SP = 3,0 [bar]; RP = 0,5 [bar]; no active auxiliary setpoint function: During normal operation the system is pressurised at 3,0 [bar].
The electropump restarts when the pressure falls below 2,7 [bar].
Setting a pressure (SP, P1, P2, P3, P4) that is too high for the pump performance may cause false water lack errors
BL; in these cases lower the set pressure.
13.2.4. Manual Menu
In manual operation, the sum of the input pressure and the maximum pressure that can be supplied must not be greater
than 6 bar.
From the main menu, hold down simultaneously the
selection menu
pressing
or
). The menu allows you to view and modify various configuration parameters: the
through the menu pages, the
Press
leave this menu and return to the main menu. Entering the manual menu by pressing the
machine into forced STOP condition. This function can be used to force
the machine to stop. In the main menu, irrespective of the parameter displayed, it is always possible to perform the following controls:
Temporary starting of the electropump.
•
Pressing the
and
as the two keys are held down. When the pump ON of pump OFF command is given, a communication appears on the display.
Starting the pump.
•
Holding down the
•
remains until the
ON of pump OFF command is given, a communication appears on the display. In case of operation in this mode for more than 5'
with no flow of liquid, an alarm overheating alarm will be triggered, with the error PH shown on the display. Once the PH error
condition is no longer present, the alarm will be reset automatically only. The reset time is 15'; if the PH error occurs more than 6
times consecutively, the reset time increases to 1h. Once it has reset further to this error, the pump will
remain in stop status until the user restarts it using the
Status
Displays the pump status.
RI: Speed setting
Sets the motor speed in rpm. Allows you to force the number of
revolutions at a predetermined value.
VP: Pressure display
Plant pressure measured in [bar] or [psi] depending on the
measuring system used.
VF: Flow display
Displays the flow in the chosen unit of measure. The measuring
unit may be l/min or gal/min see MS: Measuring system.
PO: Absorbed power display
Power absorbed by the electropump in kW.
A flashing round symbol may appear under the symbol of the
measured power PO. This symbol indicates the
pre-alarm for exceeding the allowed maximum power.
and
keys allow you respectively to increase and decrease the value of the parameter concerned.
keys at the same time causes the pump to start at speed RI and this running status remains as long
and
keys simultaneously for 2 sec. causes the pump to start at speed RI. L The running status
key is pressed. The next time the
ENGLISH
and
and
keys until the manual menu page appears (or use the
key is pressed the pump leaves the manual menu. When the pump
keys.
C1: Phase current display
Motor phase current in A.
If the maximum allowed current is exceeded, the identification C1
blinks, indicating an imminent tripping of the overload protection.
RS: Rotation speed display
Motor rotation speed in rpm.
TE: Dissipator temperature display
Shows the dissipator temperature display.